schneider LC1F500G722L

Selling Points

  • 1High-performance contactor for demanding applications.
  • 2600V 500A capacity for reliable operation.
  • 3Compatible with 120VAC 40-400Hz coil for versatile use.
  • 4Durable design for long-lasting performance.
  • 5Ideal for motor control applications in industrial settings.
Product Details
LC1F500G722L
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-3<br />AC-1<br />AC-4
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /> <= 460 V DC
[Uc] control circuit voltage
120 V AC 40...400 Hz
[Ie] rated operational current
700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1<br />500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
700 A (at 104 °F (40 °C))
Rated breaking capacity
4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
4200 A 104 °F (40 °C) - 10 s<br />3200 A 104 °F (40 °C) - 30 s<br />2400 A 104 °F (40 °C) - 1 min<br />1500 A 104 °F (40 °C) - 3 min<br />1200 A 104 °F (40 °C) - 10 min
Associated fuse rating
500 A aM at <= 440 V<br />800 A gG at <= 440 V
Average impedance
0.18 mOhm - Ith 700 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
88 W AC-1<br />45 W AC-3
Overvoltage category
III
power pole contact composition
3 NO
Auxiliary contact composition
2 NO + 2 NC
Motor power kW
250 kW at 380...400 V AC 50/60 Hz (AC-3)<br />280 kW at 415 V AC 50/60 Hz (AC-3)<br />295 kW at 440 V AC 50/60 Hz (AC-3)<br />355 kW at 500 V AC 50/60 Hz (AC-3)<br />335 kW at 660...690 V AC 50/60 Hz (AC-3)<br />335 kW at 1000 V AC 50/60 Hz (AC-3)<br />147 kW at 220...230 V AC 50/60 Hz (AC-3)<br />80 kW at 400 V AC 50/60 Hz (AC-4)
motor power HP (UL / CSA)
150 hp at 200 V AC<br />200 hp at 230 V AC<br />400 hp at 460 V AC<br />500 hp at 575 V AC
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in VA
1100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
40...65 ms closing<br />100...170 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bolted connection<br />Power circuit 2 bars 40 x 5 mm<br />Power circuit lugs-ring terminals 2 0.4 in² (240 mm²)
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
18 W
Standards
EN 60947-4-1<br />IEC 60947-4-1<br />IEC 60947-1<br />JIS C8201-4-1<br />EN 60947-1
Product Certifications
ABS<br />BV<br />DNV<br />LROS (Lloyds register of shipping)<br />CSA<br />RMRoS<br />RINA<br />CB<br />UL
Hold-in power consumption in VA
18 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz<br />Shocks contactor open9 Gn for 11 ms<br />Shocks contactor closed15 Gn for 11 ms<br />Vibrations contactor closed4 Gn, 5...300 Hz
Height
15.7 in (400 mm)
Width
9.2 in (233 mm)
Depth
9.1 in (232 mm)
Operating altitude
9842.52 ft (3000 m) without derating

Specifications may be subject to change without notice