schneider LC1F500UD

Selling Points

  • 1High-power magnetic contactor with 500A rating and 250kW power.
  • 2Panel mount design for easy installation and maintenance.
  • 33 poles (3NO) configuration for reliable motor control.
  • 4Compatible with 600VAC and 50/60 Hz frequency.
  • 5Meets multi-standards including IEC, UL, CSA, and EAC certifications.
Product Details
LC1F500UD
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-3<br />AC-1
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
250 V DC
[Ie] rated operational current
700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1<br />500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
700 A (at 104 °F (40 °C))
Rated breaking capacity
4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
4200 A 104 °F (40 °C) - 10 s<br />3200 A 104 °F (40 °C) - 30 s<br />2400 A 104 °F (40 °C) - 1 min<br />1500 A 104 °F (40 °C) - 3 min<br />1200 A 104 °F (40 °C) - 10 min
Associated fuse rating
500 A aM at <= 440 V<br />800 A gG at <= 440 V
Average impedance
0.18 mOhm - Ith 700 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
88 W AC-1<br />45 W AC-3
Overvoltage category
III
power pole contact composition
3 NO
Motor power kW
250 kW at 380...400 V AC 50/60 Hz<br />280 kW at 415 V AC 50/60 Hz<br />295 kW at 440 V AC 50/60 Hz<br />355 kW at 500 V AC 50/60 Hz<br />335 kW at 660...690 V AC 50/60 Hz<br />335 kW at 1000 V AC 50/60 Hz<br />147 kW at 220...230 V AC 50/60 Hz
Control circuit voltage limits
Operational 0.85...1.1 Uc 131 °F (55 °C))<br />Drop-out 0.2...0.35 Uc 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in W
1100 W 68 °F (20 °C))
Hold-in power consumption in W
6 W 68 °F (20 °C)
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
50...60 ms closing<br />45...60 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 40 x 5 mm<br />Power circuit lugs-ring terminals 2 0.4 in² (240 mm²)
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
6 W
Standards
JIS C8201-4-1<br />IEC 60947-4-1<br />EN 60947-1<br />IEC 60947-1<br />EN 60947-4-1
Product Certifications
CCC<br />LROS (Lloyds register of shipping)<br />BV<br />ABS<br />DNV<br />UL<br />CB<br />RMRoS<br />RINA
Control circuit type
DC standard
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Height
9.4 in (238 mm)
Width
9.2 in (233 mm)
Depth
9.1 in (232 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
25.02 lb(US) (11.35 kg)

Specifications may be subject to change without notice