schneider LC1F7804M7

Selling Points

  • 11600A at ≤ 440V AC for robust power handling.
  • 2Suitable for resistive loads and AC-1 applications.
  • 3Conforms to IEC 60947-4-1 and VDE 0110 group C standards.
  • 4220V AC control circuit with screw clamp terminals.
  • 5Withstands 8kV impulse voltage and 6240kA breaking capacity.
Product Details
LC1F7804M7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
220 V AC 40...400 Hz
[Ie] rated operational current
1600 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
1600 A (at 104 °F (40 °C))
Rated breaking capacity
6240 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3000 A 104 °F (40 °C) - 3 min<br />6250 A 104 °F (40 °C) - 10 s<br />5600 A 104 °F (40 °C) - 30 s<br />4600 A 104 °F (40 °C) - 1 min<br />2200 A 104 °F (40 °C) - 10 min
Associated fuse rating
1600 A gG at <= 440 V<br />800 A aM at <= 440 V
Average impedance
0.1 mOhm - Ith 1600 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
250 W AC-1
Overvoltage category
III
power pole contact composition
4 NO
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.2...0.4 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
5 Mcycles
Inrush power in VA
2100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
50 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
600 cyc/h 131 °F (55 °C)
Operating time
40...80 ms closing<br />130...230 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 100 x 5 mm<br />Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 513.3 lbf.in (58 N.m)
Mounting Support
Plate
Heat dissipation
44 W
Standards
JIS C8201-4-1<br />EN 60947-4-1<br />IEC 60947-1<br />EN 60947-1<br />IEC 60947-4-1
Product Certifications
DNV<br />RMRoS<br />CB<br />ABS<br />UL<br />CCC<br />LROS (Lloyds register of shipping)<br />RINA<br />BV<br />UKCA
compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Height
17.09 in (434 mm)
Width
33.9 in (862 mm)
Depth
10.04 in (255 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
105.8 lb(US) (48 kg)

Specifications may be subject to change without notice