schneider LC1F780Q7

Selling Points

  • 1High-power motor control up to 475 kW at 660-690 VAC.
  • 2Reliable operation in AC-3 category with 780 A at <=440 V AC.
  • 3Durable design with 5 million mechanical cycles and 600 cycles/hour.
  • 4Easy installation with screw clamp terminals and flexible cable options.
  • 5Compliant with IEC 60947-4-1 and VDE 0110 group C standards for safety and reliability.
Product Details
LC1F780Q7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-3<br />AC-4<br />AC-1
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
380 V AC 40...400 Hz
[Ie] rated operational current
1600 A (at <104 °F (40 °C)) at <= 440 V AC AC-1<br />780 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
1600 A (at 104 °F (40 °C))
Rated breaking capacity
6240 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3000 A 104 °F (40 °C) - 3 min<br />6250 A 104 °F (40 °C) - 10 s<br />5600 A 104 °F (40 °C) - 30 s<br />4600 A 104 °F (40 °C) - 1 min<br />2200 A 104 °F (40 °C) - 10 min
Associated fuse rating
1600 A gG at <= 440 V<br />800 A aM at <= 440 V
Average impedance
0.1 mOhm - Ith 1600 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
250 W AC-1<br />60 W AC-3
Overvoltage category
III
power pole contact composition
3 NO
Motor power kW
450 kW at 1000 V AC 50/60 Hz (AC-3)<br />400 kW at 380...400 V AC 50/60 Hz (AC-3)<br />425 kW at 415 V AC 50/60 Hz (AC-3)<br />425 kW at 440 V AC 50/60 Hz (AC-3)<br />450 kW at 500 V AC 50/60 Hz (AC-3)<br />475 kW at 660...690 V AC 50/60 Hz (AC-3)<br />220 kW at 220...230 V AC 50/60 Hz (AC-3)<br />110 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.2...0.4 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
5 Mcycles
Inrush power in VA
2100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
50 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
600 cyc/h 131 °F (55 °C)
Operating time
40...80 ms closing<br />130...230 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 100 x 5 mm<br />Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 513.3 lbf.in (58 N.m)
Mounting Support
Plate
Heat dissipation
44 W
Standards
EN 60947-1<br />IEC 60947-1<br />JIS C8201-4-1<br />EN 60947-4-1<br />IEC 60947-4-1
Product Certifications
LROS (Lloyds register of shipping)<br />DNV<br />RINA<br />RMRoS<br />CB<br />ABS<br />BV<br />CCC<br />UL<br />UKCA
compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Height
17.09 in (434 mm)
Width
27.6 in (702 mm)
Depth
10.04 in (255 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
87.08 lb(US) (39.5 kg)