Product Model
LC1K0610D7

Selling Points
- 1The LC1K0610D7 is designed for DIN rail mounting, making it perfect for space-constrained applications.
- 2Supports up to 3 kW of power, ensuring efficient motor control.
- 3Built with robust materials and rated for 690 V ac, providing reliable performance.
- 4Part of Schneider Electric's Better World range, ensuring a greener product choice.
- 5Operates between -25°C and +50°C, suitable for various environmental conditions.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | TeSys K | Range | TeSys |
Product or Component Type | Contactor | Device short name | LC1K |
Contactor application | Motor control | Utilisation category | AC-3<br />AC-4<br />AC-3e |
Poles description | 3P | Pole contact composition | 3 NO |
[Ie] rated operational current | 6 A at <= 440 V AC AC-3 for power circuit<br />6 A at <= 440 V AC AC-3e for power circuit | Auxiliary contact composition | 1 NO |
Control circuit type | AC 50/60 Hz | Motor power kW | 1.5 kW 220...230 V AC 50/60 Hz AC-3<br />2.2 kW 380...415 V AC 50/60 Hz AC-3<br />3 kW 440/690 V AC 50/60 Hz AC-3<br />1.5 kW 220...230 V AC 50/60 Hz AC-3e<br />2.2 kW 380...415 V AC 50/60 Hz AC-3e<br />3 kW 440/690 V AC 50/60 Hz AC-3e<br />1.5 kW 400 V AC 50/60 Hz AC-4 |
Auxiliary contacts type | Instantaneous 1 NO | [Uc] control circuit voltage | 42 V AC 50/60 Hz |
Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) | [Ui] rated insulation voltage | Power circuit 600 V UL 508<br />Power circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-5-1<br />Signalling circuit 600 V UL 508<br />Power circuit 600 V CSA C22.2 No 14<br />Signalling circuit 600 V CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage | 8 kV | Overvoltage category | III |
Mounting Support | Rail<br />Plate | Standards | EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1 |
IP degree of protection | IP2X VDE 0106 | Protective treatment | TC IEC 60068<br />TC DIN 50016 |
Flame retardance | V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102 | Connections - terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end<br /> screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end |
Tightening torque | 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2<br /> 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm<br /> 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2 | [Ue] rated operational voltage | Power circuit 690 V AC 50/60 Hz<br />Signalling circuit <= 690 V AC 50/60 Hz |
[Ith] conventional free air thermal current | 20 A (at 122 °F (50 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit | Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110<br />110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947 |
Rated breaking capacity | 110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947 | Associated fuse rating | 25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660 |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | Inrush power in VA | 30 VA (at 68 °F (20 °C)) |
Hold-in power consumption in VA | 4.5 VA (at 68 °F (20 °C)) | Heat dissipation | 1.3 W |
Operating time | 10...20 ms coil de-energisation and NO opening<br />10...20 ms coil energisation and NO closing | Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 10 Mcycles | Maximum operating rate | 3600 cyc/h |
Minimum switching current | 5 mA for signalling circuit | Minimum switching voltage | 17 V for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit | Height | 2.3 in (58 mm) |
Width | 1.8 in (45 mm) | Depth | 2.2 in (57 mm) |
Net Weight | 0.40 lb(US) (0.18 kg) | Product Certifications | CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA |
Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) | Operating altitude | 6561.68 ft (2000 m) without derating |
Specifications may be subject to change without notice