Product Model
LC1K09105B7

Selling Points
- 1Compact design with DIN-rail compatibility.
- 2Rated for 4kW at 400V AC3, 9A.
- 3Includes a 24V 50/60Hz AC coil.
- 4Features a built-in 1NO auxiliary contact.
- 5Compliant with multi-standards (IEC, UL, CSA, CCC, EAC, Marine).
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | TeSys K | Range | TeSys |
Product or Component Type | Contactor | Contactor application | Resistive load<br />Motor control |
Utilisation category | AC-1<br />AC-4<br />AC-3 | Poles description | 3P |
Pole contact composition | 3 NO | [Ie] rated operational current | 16 A (at <122 °F (50 °C)) at <= 440 V AC AC-1 for power circuit<br />9 A at <= 440 V AC AC-3 for power circuit |
Auxiliary contact composition | 1 NO | Control circuit type | AC 50/60 Hz |
Motor power kW | 2.2 kW 220...230 V AC 50/60 Hz AC-3<br />4 kW 380...415 V AC 50/60 Hz AC-3<br />4 kW 440 V AC 50/60 Hz AC-3<br />4 kW 480 V AC 50/60 Hz AC-3<br />4 kW 500...600 V AC 50/60 Hz AC-3<br />4 kW 660...690 V AC 50/60 Hz AC-3<br />2.2 kW 400 V AC 50/60 Hz AC-4 | Auxiliary contacts type | Instantaneous 1 NO |
[Uc] control circuit voltage | 24 V AC 50/60 Hz | Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) |
Overvoltage category | III | Standards | EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ |
Protective treatment | TC IEC 60068<br />TC DIN 50016 | Flame retardance | V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102 |
Connections - terminals | solder pins 1.5 x 0.9 mm | [Ith] conventional free air thermal current | 16 A (at 122 °F (50 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit |
Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110<br />110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947 | Rated breaking capacity | 110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947 |
Associated fuse rating | 25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660 | Average impedance | 3 mOhm - Ith 16 A 50 Hz for power circuit |
Inrush power in VA | 30 VA (at 68 °F (20 °C)) | Hold-in power consumption in VA | 4.5 VA (at 68 °F (20 °C)) |
Heat dissipation | 1.3 W | Operating time | 10...20 ms coil de-energisation and NO opening<br />10...20 ms coil energisation and NO closing |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Maximum operating rate | 3600 cyc/h |
Minimum switching current | 5 mA for signalling circuit | Minimum switching voltage | 17 V for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit | Height | 2.3 in (58 mm) |
Width | 1.8 in (45 mm) | Depth | 2.2 in (57 mm) |
Product Certifications | CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA | Operating altitude | 6561.68 ft (2000 m) without derating |
Specifications may be subject to change without notice