schneider LC1K0910B7TQ

Selling Points

  • 1Compact design for DIN rail or panel mounting.
  • 224V AC coil for versatile control circuit compatibility.
  • 39A current rating for reliable motor control.
  • 4Integrated 1NO auxiliary contact for added functionality.
  • 5Compliant with multi-standards (IEC, UL, CSA) and certified Green Premium.
Product Details
LC1K0910B7TQ
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Product or Component Type
Contactor
Device short name
LC1K
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-3<br />AC-3e<br />AC-1<br />AC-4
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC <= 400 Hz<br />Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current
9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit<br />20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type
AC 50/60 Hz standard
[Uc] control circuit voltage
24 V AC 50/60 Hz
Motor power kW
2.2 kW 220...230 V AC 50/60 Hz AC-3<br />4 kW 380...415 V AC 50/60 Hz AC-3<br />4 kW 440/690 V AC 50/60 Hz AC-3<br />2.2 kW 220...230 V AC 50/60 Hz AC-3e<br />4 kW 380...415 V AC 50/60 Hz AC-3e<br />4 kW 440/690 V AC 50/60 Hz AC-3e<br />2.2 kW 220...230 V AC 50/60 Hz AC-4<br />4 kW 380...415 V AC 50/60 Hz AC-4<br />4 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition
1 NO
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
20 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity
110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit<br />80 A - 1 s for signalling circuit<br />90 A - 500 ms for signalling circuit<br />110 A - 100 ms for signalling circuit
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947<br />10 A gG for control circuit conforming to VDE 0660<br />25 A gG at <= 440 V for power circuit
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage
Control circuit 690 V BS 5424<br />Control circuit 690 V IEC 60947<br />Power circuit 690 V BS 5424<br />Power circuit 690 V IEC 60947<br />Power circuit 690 V NF C 20-040<br />Control circuit 750 V VDE 0110 group C<br />Power circuit 750 V VDE 0110 group C<br />Control circuit 600 V CSA C22.2 No 14<br />Power circuit 600 V UL 508 CSA C22.2 No 14
Insulation resistance
> 10 MOhm for control circuit
Inrush power in VA
30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA
4.5 VA 50/60 Hz (at 68 °F (20 °C))
Control circuit voltage limits
Operational: 0.8...1.15 Uc at 50/60 Hz (at <122 °F (50 °C))<br />Drop-out: >= 0.20 Uc at 50/60 Hz (at <122 °F (50 °C))
Connections - terminals
screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end<br /> screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate
3600 cyc/h
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Minimum switching current
5 mA for control circuit
Minimum switching voltage
17 V for control circuit
Mounting Support
Rail<br />Plate
Operating time
10...20 ms coil de-energisation and NO opening<br />15...25 ms coil de-energisation and NC opening<br />10...20 ms between energisation of coil and closing of NO contact<br />5...15 ms coil energisation and NC opening
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
10 Mcycles
Electrical durability
1.3 Mcycles 9 A AC-3 <= 440 V<br />1.3 Mcycles 9 A AC-3e <= 440 V<br />0.16 Mcycles 20 A AC-1 <= 690 V<br />0.02 Mcycles 54 A AC-4 <= 440 V
Height
2.3 in (58 mm)
Width
1.8 in (45 mm)
Depth
2.2 in (57 mm)
Net Weight
0.40 lb(US) (0.18 kg)
Standards
EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1
Product Certifications
CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA
Ambient Air Temperature for Storage
-58…176 °F (-50…80 °C)
Operating altitude
6561.68 ft (2000 m) without derating
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
Class C2 conforming to NF F 16-101<br />Class C2 conforming to NF F 16-102<br />V1 conforming to UL 94

Specifications may be subject to change without notice