schneider LC1K0910L7

Selling Points

  • 1Compact design for easy installation.
  • 2High power rating of 4 kW at 660 to 690 VAC.
  • 3Compatible with programmable controller outputs.
  • 4Low consumption and energy-efficient operation.
  • 5Robust construction with 3600 cycles/hr operating cycles.
Product Details
LC1K0910L7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Product or Component Type
Contactor
Device Application
Control
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-3<br />AC-3e<br />AC-1<br />AC-4
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC <= 400 Hz<br />Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current
9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit<br />20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
200...208 V AC 50/60 Hz
Motor power kW
2.2 kW 220...230 V AC 50/60 Hz AC-3<br />4 kW 380...415 V AC 50/60 Hz AC-3<br />4 kW 440/690 V AC 50/60 Hz AC-3<br />2.2 kW 220...230 V AC 50/60 Hz AC-3e<br />4 kW 380...415 V AC 50/60 Hz AC-3e<br />4 kW 440/690 V AC 50/60 Hz AC-3e<br />2.2 kW 220...230 V AC 50/60 Hz AC-4<br />4 kW 380...415 V AC 50/60 Hz AC-4<br />4 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition
1 NO
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
20 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity
110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit<br />80 A - 1 s for signalling circuit<br />90 A - 500 ms for signalling circuit<br />110 A - 100 ms for signalling circuit
Associated fuse rating
25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation resistance
> 10 MOhm for signalling circuit
Inrush power in VA
30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA
4.5 VA (at 68 °F (20 °C))
Heat dissipation
1.3 W
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
Connections - terminals
screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end<br /> screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate
3600 cyc/h
Auxiliary contacts type
Instantaneous 1 NO
Signalling circuit frequency
<= 400 Hz
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Operating time
10...20 ms coil de-energisation and NO opening<br />10...20 ms coil energisation and NO closing
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non overlap distance
0.02 in (0.5 mm)
Mechanical durability
10 Mcycles
Electrical durability
1.3 Mcycles 9 A AC-3 <= 440 V<br />1.3 Mcycles 9 A AC-3e <= 440 V<br />0.16 Mcycles 20 A AC-1 <= 690 V<br />0.02 Mcycles 54 A AC-4 <= 440 V
Mechanical robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height
2.3 in (58 mm)
Width
1.8 in (45 mm)
Depth
2.2 in (57 mm)
Standards
EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ
Product Certifications
CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA
Protective treatment
TC IEC 60068<br />TC DIN 50016
Operating altitude
6561.68 ft (2000 m) without derating
Flame retardance
V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102

Specifications may be subject to change without notice