schneider LC1K12004U7

Selling Points

  • 1Compact design with 45mm width for easy DIN-rail mounting.
  • 2Certified to multiple standards including IEC, UL, CSA, CCC, and EAC.
  • 3Green Premium compliant with RoHS/REACh, reducing environmental impact.
  • 4Suitable for non-inductive load control applications up to 20A/690V AC-1.
  • 5High reliability with operating rates up to 600 cycles/hour and environments up to 50°C.
Product Details
LC1K12004U7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
TeSys K
Range
TeSys
Product name
TeSys K
Device Application
Control
Product or Component Type
Contactor
Utilisation category
AC-1
Poles description
4P
Pole contact composition
4 NO
[Ie] rated operational current
20 A (at <122 °F (50 °C)) at <= 440 V AC AC-1 for power circuit<br />16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit
Signalling circuit frequency
<= 400 Hz
Contactor application
Resistive load
Control circuit voltage limits
Operational: 0.85...1.1 Uc (at <122 °F (50 °C))<br />Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C))
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230...240 V AC 50/60 Hz
Mechanical robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Standards
EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1
Protective treatment
TC IEC 60068<br />TC DIN 50016
Overvoltage category
III
Product Certifications
CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA
Operating altitude
6561.68 ft (2000 m) without derating
[Ith] conventional free air thermal current
20 A (at 122 °F (50 °C)) for power circuit
Irms rated making capacity
144 A AC for power circuit conforming to NF C 63-110<br />144 A AC for power circuit conforming to IEC 60947
Rated breaking capacity
110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947
Associated fuse rating
25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Inrush power in VA
30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA
4.5 VA (at 68 °F (20 °C))
Operating time
10...20 ms coil de-energisation and NO opening<br />10...20 ms coil energisation and NO closing
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum operating rate
3600 cyc/h
Height
2.3 in (58 mm)
Width
1.8 in (45 mm)
Depth
2.2 in (57 mm)
compatibility code
LC1K
Heat dissipation
1.3 W
Flame retardance
V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102

Specifications may be subject to change without notice