Product Model
LC2K06017E72

Selling Points
- 1High Performance: Designed for efficient operation in industrial environments.
- 2Reliability: Meets stringent safety standards with a high B10d value of 200,000 cycles.
- 3Compliance: Conforms to IEC 60947, CSA C22.2 No 14, and UL 508 standards.
- 4Versatile Use: Suitable for various applications including motor control and signaling circuits.
- 5Sustainable Design: Part of Schneider Electric's commitment to sustainability and circular economy practices.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Product name | TeSys K |
Product or Component Type | Reversing contactor | Device short name | LC2K |
Device Application | Control | Contactor application | Motor control |
Utilisation category | AC-4<br />AC-3 | Device presentation | Preassembled with reversing power busbar |
Poles description | 3P | power pole contact composition | 3 NO |
[Ue] rated operational voltage | Power circuit 690 V AC 50/60 Hz<br />Signalling circuit <= 690 V AC 50/60 Hz | [Ie] rated operational current | 6 A at <= 440 V AC AC-3 for power circuit |
Motor power kW | 1.5 kW 220...230 V AC 50/60 Hz<br />2.2 kW 380...415 V AC 50/60 Hz<br />3 kW 440 V AC 50/60 Hz<br />3 kW 480 V AC 50/60 Hz<br />3 kW 500...600 V AC 50/60 Hz<br />3 kW 660...690 V AC 50/60 Hz | Control circuit type | AC 50/60 Hz |
[Uc] control circuit voltage | 48 V AC 50/60 Hz | Auxiliary contact composition | 1 NC |
[Uimp] rated impulse withstand voltage | 8 kV | Overvoltage category | III |
[Ith] conventional free air thermal current | 20 A (at 122 °F (50 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit | Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110<br />110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947 |
Rated breaking capacity | 110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947 | [Icw] rated short-time withstand current | 90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />80 A - 1 s for signalling circuit<br />90 A - 500 ms for signalling circuit<br />110 A - 100 ms for signalling circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit |
Associated fuse rating | 25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660 | Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
[Ui] rated insulation voltage | Power circuit 600 V UL 508<br />Power circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-5-1<br />Signalling circuit 600 V UL 508<br />Power circuit 600 V CSA C22.2 No 14<br />Signalling circuit 600 V CSA C22.2 No 14 | Electrical durability | 1.3 Mcycles 6 A AC-3 <= 440 V |
Interlocking type | Mechanical | Mounting Support | Rail<br />Plate |
Standards | NF C 63-110<br />BS 5424<br />VDE 0660<br />IEC 60947 | Product Certifications | CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA |
Connections - terminals | Faston terminals 2 2.8 mm<br /> Faston terminals 1 6.35 mm | Operating time | 10...20 ms coil energisation and NO closing<br />10...20 ms coil de-energisation and NO opening |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 5 Mcycles |
Maximum operating rate | 3600 cyc/h | Coil technology | Built-in bidirectional peak limiting diode suppressor |
Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) | Inrush power in VA | 30 VA (at 68 °F (20 °C)) |
Hold-in power consumption in VA | 4.5 VA (at 68 °F (20 °C)) | Heat dissipation | 1.3 W |
Auxiliary contacts type | Instantaneous 1 NC | Signalling circuit frequency | <= 400 Hz |
Minimum switching current | 5 mA for signalling circuit | Minimum switching voltage | 17 V for signalling circuit |
Non overlap distance | 0.02 in (0.5 mm) | Insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 VDE 0106 | Protective treatment | TC IEC 60068<br />TC DIN 50016 |
Ambient Air Temperature for Operation | -13…122 °F (-25…50 °C) | Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) |
Operating altitude | 6561.68 ft (2000 m) without derating | Flame retardance | V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102 |
Mechanical robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 | Height | 2.3 in (58 mm) |
Width | 3.5 in (90 mm) | Depth | 2.2 in (57 mm) |
Net Weight | 0.86 lb(US) (0.39 kg) |
Specifications may be subject to change without notice