schneider LC2K090045Q7

Selling Points

  • 1Designed to withstand 0.18 Mcycles at 20 A AC-1 up to 440 V.
  • 2Ensures safe and reliable operation with mechanical interlocking.
  • 3Meets international standards with CB Scheme, CCC, and UL certifications.
  • 4Compatible with plate rail mounting for easy installation.
  • 5Suitable for 380 to 400VAC coil applications, providing flexibility in electrical systems.
Product Details
LC2K090045Q7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Product name
TeSys K
Product or Component Type
Changeover contactor
Device short name
LC2K
Device Application
Control
Contactor application
Resistive load
Utilisation category
AC-1
Device presentation
Preassembled with reversing power busbar
Poles description
4P
power pole contact composition
4 NO
[Ue] rated operational voltage
Power circuit 690 V AC 50/60 Hz
[Ie] rated operational current
20 A (at <122 °F (50 °C)) at <= 440 V AC AC-1 for power circuit<br />16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
380...400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
20 A (at 122 °F (50 °C)) for power circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110<br />110 A AC for power circuit conforming to IEC 60947
Rated breaking capacity
110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit
Associated fuse rating
25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage
Power circuit 600 V UL 508<br />Power circuit 690 V IEC 60947-4-1<br />Power circuit 600 V CSA C22.2 No 14
Electrical durability
0.18 Mcycles 20 A AC-1 <= 440 V
Interlocking type
Mechanical
Mounting Support
Plate<br />Rail
Standards
BS 5424<br />NF C 63-110<br />IEC 60947<br />VDE 0660
Product Certifications
CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA
Connections - terminals
solder pins 1.5 x 0.9 mm
Operating time
10...20 ms coil energisation and NO closing<br />10...20 ms coil de-energisation and NO opening
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
5 Mcycles
Maximum operating rate
3600 cyc/h
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C))
Inrush power in VA
30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA
4.5 VA (at 68 °F (20 °C))
Heat dissipation
1.3 W
IP degree of protection
IP20 VDE 0106
Protective treatment
TC IEC 60068<br />TC DIN 50016
Ambient Air Temperature for Operation
-13…122 °F (-25…50 °C)
Ambient Air Temperature for Storage
-58…176 °F (-50…80 °C)
Operating altitude
6561.68 ft (2000 m) without derating
Flame retardance
V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102
Mechanical robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height
2.3 in (58 mm)
Width
3.5 in (90 mm)
Depth
2.2 in (57 mm)
Net Weight
0.84 lb(US) (0.38 kg)

Specifications may be subject to change without notice