schneider LC7K06015B7

Selling Points

  • 1High-performance 3P AC-3 contactor for reliable electrical control.
  • 2Supports up to 440V and 6A, ensuring robust operation in various applications.
  • 3Equipped with a 24VAC coil for easy integration and control.
  • 4Includes 1 NC auxiliary contact for added functionality and versatility.
  • 5Designed for long-lasting performance with high cycle ratings.
Product Details
LC7K06015B7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
TeSys K
Range
TeSys
Product name
TeSys K
Device Application
Control
Product or Component Type
Contactor
Utilisation category
AC-3<br />AC-4
Poles description
3P
Pole contact composition
3 NO
[Uc] control circuit voltage
24 V AC 50/60 Hz
Signalling circuit frequency
<= 400 Hz
Non overlap distance
0.02 in (0.5 mm)
Contactor application
Motor control
Auxiliary contact composition
1 NC
Control circuit voltage limits
Operational: 0.85...1.1 Uc (at <122 °F (50 °C))<br />Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
Control circuit type
AC 50/60 Hz silent
Connections - terminals
solder pins 1.5 x 0.9 mm
Electrical durability
1.3 Mcycles 6 A AC-3 <= 440 V
Mechanical robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Standards
EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1
IP degree of protection
IP2X VDE 0106
Protective treatment
TC IEC 60068<br />TC DIN 50016
[Ui] rated insulation voltage
Power circuit 600 V UL 508<br />Power circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-5-1<br />Signalling circuit 600 V UL 508<br />Power circuit 600 V CSA C22.2 No 14<br />Signalling circuit 600 V CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
Mounting Support
Printed circuit boards
Product Certifications
CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA
Ambient Air Temperature for Storage
-58…176 °F (-50…80 °C)
Operating altitude
6561.68 ft (2000 m) without derating
[Ue] rated operational voltage
Power circuit 690 V AC 50/60 Hz<br />Signalling circuit <= 690 V AC 50/60 Hz
[Ith] conventional free air thermal current
20 A (at 122 °F (50 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110<br />110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity
110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947
Associated fuse rating
25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Inrush power in VA
3 VA (at 68 °F (20 °C))
Hold-in power consumption in VA
3 VA (at 68 °F (20 °C))
Operating time
30...40 ms coil energisation and NO closing<br />30 ms coil de-energisation and NO opening
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
10 Mcycles
Maximum operating rate
3600 cyc/h
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Insulation resistance
> 10 MOhm for signalling circuit
Height
2.3 in (58 mm)
Width
1.8 in (45 mm)
Depth
2.2 in (57 mm)
compatibility code
LC7K
Motor power kW
1.5 kW 220...230 V AC 50/60 Hz<br />2.2 kW 380...415 V AC 50/60 Hz<br />3 kW 440 V AC 50/60 Hz<br />3 kW 480 V AC 50/60 Hz<br />3 kW 500...600 V AC 50/60 Hz<br />3 kW 660...690 V AC 50/60 Hz
Heat dissipation
3 W
Flame retardance
V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102

Specifications may be subject to change without notice