ParameterValueParameterValue
Range of Product
Harmony Control Relays
Relay Type
Multifunction control relay
Product Specific Application
For 3-phase supply
Relay name
RM17TU
Relay monitored parameters
Undervoltage detection<br />Phase sequence<br />Phase failure detection
Measurement range
208...480 V AC
time delay
Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
Output contacts
1 C/O
Nominal output current
5 A
Contacts type and composition
1 C/O
[Uc] control circuit voltage
208...480 V
[Un] rated nominal voltage
, self-powered
Supply voltage limits
183…528 V AC
Reset time
1500 ms time delay
Maximum switching voltage
250 V AC<br />250 V DC
Switching capacity in VA
1250 VA
Minimum switching current
10 mA 5 V DC
Maximum switching current
5 A AC<br />5 A DC
Control circuit voltage limits
- 12 % + 10 % Un
Power consumption in VA
0…22 VA 400 V AC 50 Hz
Control circuit frequency
50...60 Hz +/- 10 %
Measurement voltage limits
183…528 V AC
Hysteresis
2 %
delay at power up
650 ms
Maximum measuring cycle
150 ms measurement cycle as true rms value
Threshold adjustment voltage
2...20 % of Un selected<br />-2...-12 % in the range 208 V AC<br />-2...-17 % in the range 220 V AC
Voltage range
208...480 V phase to phase
Repeat accuracy
0.5 % input and measurement circuit<br />3 % time delay
Measurement error
< 0.05 %/°C with temperature variation<br />< 1 % over the whole range with voltage variation
Phase failure sensitivity
0.7 Un
Response time
< 200 ms (in the event of a fault)
Insulation resistance
> 500 MOhm 500 V DC IEC 60255-5<br />> 500 MOhm 500 V DC IEC 60664-1
[Ui] rated insulation voltage
400 V IEC 60664-1
Supply frequency
50/60 Hz +/- 10 %
Operating position
Any position without derating
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end<br />Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end<br />Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end<br />Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Tightening torque
5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
Housing material
Self-extinguishing plastic
Local signalling
for power ON LED (green)<br /> for relay ON LED (yellow)
Mounting support
35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability
100000 cycles
Mechanical durability
30000000 cycles
Operating rate
<= 360 operations/hour full load
Utilisation category
AC-12 IEC 60947-5-1<br />AC-13 IEC 60947-5-1<br />AC-14 IEC 60947-5-1<br />AC-15 IEC 60947-5-1<br />DC-12 IEC 60947-5-1<br />DC-13 IEC 60947-5-1
Safety reliability data
MTTFd = 502.2 years<br />B10d = 470000
Width
0.7 in (17.5 mm)
Net Weight
0.29 lb(US) (0.13 kg)
Control Type
Without test button
Electromagnetic compatibility
Emission standard for industrial environments conforming to IEC 61000-6-4<br />Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3<br />Immunity for industrial environments conforming to IEC 61000-6-2
Standards
IEC 60255-1
Product Certifications
GL<br />GOST<br />UL<br />C-tick<br />CSA
marking
CE
Directives
73/23/EEC - low voltage directive<br />89/336/EEC - electromagnetic compatibility
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient air temperature for operation
-4…122 °F (-20…50 °C)
Relative humidity
95 % 131 °F (55 °C) IEC 60068-2-30
Vibration resistance
0.35 mm 5…57.6 Hz)IEC 60068-2-6<br />1 gn 57.6…150 Hz)IEC 60255-21-1
Shock resistance
15 gn 11 ms IEC 60255-21-1
IP degree of protection
IP20 IEC 60529 terminals)<br />IP30 IEC 60529 casing)
Pollution degree
3 IEC 60664-1
Overvoltage category
III IEC 60664-1
Dielectric test voltage
2 kV AC 50 Hz, 1 min IEC 60255-5<br />2 kV AC 50 Hz, 1 min IEC 60664-1
Non-dissipating shock wave
4 kV IEC 60255-5<br />4 kV IEC 60664-1<br />4 kV IEC 61000-4-5

Specifications may be subject to change without notice