schneider RM17UAS14

Selling Points

  • 10.1...10 seconds with ±10% accuracy.
  • 2±10% measurement accuracy and ±0.5% repeat accuracy.
  • 3Self-extinguishing plastic housing with 100,000 cycles electrical durability.
  • 4Mountable on symmetrical DIN rail (EN/IEC 60715).
  • 5Compliant with IEC 60947-5-1 and IEC 60255-5 standards.
Product Details
RM17UAS14
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony Control Relays
Relay Type
Voltage control relay
Product or Component Type
Voltage control relay
Product Specific Application
For single-phase and DC supply
Relay name
RM17UAS
Relay monitored parameters
Overvoltage or undervoltage detection
time delay
Adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault
Switching capacity in VA
1250 VA
Measurement range
9...15 V DC
Contacts type and composition
1 C/O
Reset time
1500 ms time delay
Maximum switching voltage
250 V AC/DC
Minimum switching current
10 mA 5 V DC
Maximum switching current
5 A AC/DC
Supply voltage limits
7…20 V DC
Maximum power consumption in W
1 W DC
Immunity to microbreaks
20 ms 12 V
Output contacts
1 C/O
Nominal output current
5 A
Hysteresis
5…20 % threshold setting
Measurement accuracy
+/- 10 % of the full scale value
Polarity
Non reversible polarity on DC supply
delay at power up
1000 ms DC
Repeat accuracy
+/- 0.5 % input and measurement circuit<br />+/- 1 % time delay
Measurement error
< 1 % over the whole range with voltage variation<br />0.2 %/°C with temperature variation
Quality labels
CE
Insulation resistance
> 500 MOhm 500 V DC IEC 60255-5<br />> 500 MOhm 500 V DC IEC 60664-1
Operating position
Any position without derating
Local signalling
for power ON LED (green)<br /> for relay ON LED (yellow)
Overvoltage category
III IEC 60664-1
[Ui] rated insulation voltage
250 V IEC 60664-1<br />400 V IEC 60664-1
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end<br />Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end<br />Screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end<br />Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Tightening torque
5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
Housing material
Self-extinguishing plastic
Mounting support
35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability
100000 cycles
Mechanical durability
30000000 cycles
Operating rate
<= 360 operations/hour full load
Utilisation category
AC-12 IEC 60947-5-1<br />AC-13 IEC 60947-5-1<br />AC-14 IEC 60947-5-1<br />AC-15 IEC 60947-5-1<br />DC-12 IEC 60947-5-1<br />DC-13 IEC 60947-5-1<br />DC-14 IEC 60947-5-1
[Un] rated nominal voltage
, self-powered
Control Type
Without test button
Width
0.7 in (17.5 mm)
Net Weight
0.18 lb(US) (0.08 kg)
Electromagnetic compatibility
Emission standard for industrial environments conforming to IEC 61000-6-4<br />Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3<br />Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Ambient air temperature for operation
-4…122 °F (-20…50 °C)
Vibration resistance
0.35 mm 5…57.6 Hz)IEC 60068-2-6<br />1 gn 57.6…150 Hz)IEC 60255-21-1
Shock resistance
5 gn IEC 60068-2-27
Standards
IEC 60255-6
Product Certifications
CSA<br />C-tick<br />GL<br />UL<br />GOST
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Relative humidity
95 % 131 °F (55 °C) IEC 60068-2-30
IP degree of protection
IP20 IEC 60529 terminals)<br />IP30 IEC 60529 casing)
Pollution degree
3 IEC 60664-1
Directives
73/23/EEC - low voltage directive<br />89/336/EEC - electromagnetic compatibility
Dielectric test voltage
2 kV AC 50 Hz, 1 min IEC 60255-5<br />2 kV AC 50 Hz, 1 min IEC 60664-1
Non-dissipating shock wave
4 kV IEC 60255-5<br />4 kV IEC 60664-1<br />4 kV IEC 61000-4-5

Specifications may be subject to change without notice