Product Model
RM17UAS14

Selling Points
- 10.1...10 seconds with ±10% accuracy.
- 2±10% measurement accuracy and ±0.5% repeat accuracy.
- 3Self-extinguishing plastic housing with 100,000 cycles electrical durability.
- 4Mountable on symmetrical DIN rail (EN/IEC 60715).
- 5Compliant with IEC 60947-5-1 and IEC 60255-5 standards.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Harmony Control Relays | Relay Type | Voltage control relay |
Product or Component Type | Voltage control relay | Product Specific Application | For single-phase and DC supply |
Relay name | RM17UAS | Relay monitored parameters | Overvoltage or undervoltage detection |
time delay | Adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault | Switching capacity in VA | 1250 VA |
Measurement range | 9...15 V DC | Contacts type and composition | 1 C/O |
Reset time | 1500 ms time delay | Maximum switching voltage | 250 V AC/DC |
Minimum switching current | 10 mA 5 V DC | Maximum switching current | 5 A AC/DC |
Supply voltage limits | 7…20 V DC | Maximum power consumption in W | 1 W DC |
Immunity to microbreaks | 20 ms 12 V | Output contacts | 1 C/O |
Nominal output current | 5 A | Hysteresis | 5…20 % threshold setting |
Measurement accuracy | +/- 10 % of the full scale value | Polarity | Non reversible polarity on DC supply |
delay at power up | 1000 ms DC | Repeat accuracy | +/- 0.5 % input and measurement circuit<br />+/- 1 % time delay |
Measurement error | < 1 % over the whole range with voltage variation<br />0.2 %/°C with temperature variation | Quality labels | CE |
Insulation resistance | > 500 MOhm 500 V DC IEC 60255-5<br />> 500 MOhm 500 V DC IEC 60664-1 | Operating position | Any position without derating |
Local signalling | for power ON LED (green)<br /> for relay ON LED (yellow) | Overvoltage category | III IEC 60664-1 |
[Ui] rated insulation voltage | 250 V IEC 60664-1<br />400 V IEC 60664-1 | Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end<br />Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end<br />Screw terminals, 1 x 0.2...2 x 2.5 mm² AWG 24...AWG 12) flexible with cable end<br />Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end |
Tightening torque | 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1 | Housing material | Self-extinguishing plastic |
Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 | Electrical durability | 100000 cycles |
Mechanical durability | 30000000 cycles | Operating rate | <= 360 operations/hour full load |
Utilisation category | AC-12 IEC 60947-5-1<br />AC-13 IEC 60947-5-1<br />AC-14 IEC 60947-5-1<br />AC-15 IEC 60947-5-1<br />DC-12 IEC 60947-5-1<br />DC-13 IEC 60947-5-1<br />DC-14 IEC 60947-5-1 | [Un] rated nominal voltage | , self-powered |
Control Type | Without test button | Width | 0.7 in (17.5 mm) |
Net Weight | 0.18 lb(US) (0.08 kg) | Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4<br />Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3<br />Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
Ambient air temperature for operation | -4…122 °F (-20…50 °C) | Vibration resistance | 0.35 mm 5…57.6 Hz)IEC 60068-2-6<br />1 gn 57.6…150 Hz)IEC 60255-21-1 |
Shock resistance | 5 gn IEC 60068-2-27 | Standards | IEC 60255-6 |
Product Certifications | CSA<br />C-tick<br />GL<br />UL<br />GOST | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Relative humidity | 95 % 131 °F (55 °C) IEC 60068-2-30 | IP degree of protection | IP20 IEC 60529 terminals)<br />IP30 IEC 60529 casing) |
Pollution degree | 3 IEC 60664-1 | Directives | 73/23/EEC - low voltage directive<br />89/336/EEC - electromagnetic compatibility |
Dielectric test voltage | 2 kV AC 50 Hz, 1 min IEC 60255-5<br />2 kV AC 50 Hz, 1 min IEC 60664-1 | Non-dissipating shock wave | 4 kV IEC 60255-5<br />4 kV IEC 60664-1<br />4 kV IEC 61000-4-5 |
Specifications may be subject to change without notice