schneider RM22TG20

Selling Points

  • 1Phase Sequence Monitoring: Detects phase sequence to ensure proper electrical operation.
  • 2Phase Failure Detection: Automatically detects phase failures for quick fault identification.
  • 3Wide Voltage Range: Operates within 183-528V AC, suitable for various industrial applications.
  • 4Compact Design: Slim form-factor with 22.5mm width, easy to install on DIN rail.
  • 5Reliable Contacts: 2 C/O contacts with cadmium-free material for long-lasting performance.
Product Details
RM22TG20
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony Control Relays
Relay Type
Control relay
Product or Component Type
3-phase control relay
Phase
3 phase
Relay name
RM22TG
Relay monitored parameters
Phase sequence<br />Phase failure detection (2 or more phase cut)
Time delay type
Without
Switching capacity in VA
2000 VA
Measurement range
208...480 V voltage AC
Contacts type and composition
2 C/O
Reset time
1500 ms at maximum voltage
Maximum switching voltage
250 V AC
Minimum switching current
10 mA 5 V DC
Maximum switching current
8 A AC
[Us] Rated Supply Voltage
AC/DC
Supply voltage limits
183…528 V AC
operating limits
183...528 V AC
Power consumption in VA
15 VA 480 V AC 60 Hz
Voltage detection threshold
< 100 V AC
supply voltage frequency
50...60 Hz +/- 10 %
Output contacts
2 C/O
Run-up delay at power-up
650 ms
Response time
<= 200 ms
Overvoltage category
III IEC 60664-1<br />III UL 508
Insulation resistance
> 100 MOhm 500 V DC IEC 60255-27
Mounting position
Any position
Connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end<br />Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end<br />Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end<br />Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Tightening torque
5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
Housing material
Self-extinguishing plastic
Status LED
LED (Yellow) relay ON<br />LED (Green) power ON
Mounting support
35 mm DIN rail conforming to IEC 60715
Electrical durability
100000 cycles
Mechanical durability
10000000 cycles
Utilisation category
AC-15 IEC 60947-5-1<br />DC-13 IEC 60947-5-1<br />AC-1 IEC 60947-4-1<br />DC-1 IEC 60947-4-1
[Un] rated nominal voltage
, self-powered
Safety reliability data
MTTFd = 924.6 years<br />B10d = 850000
Contacts material
Cadmium free
Control Type
With test button
Width
0.9 in (22.5 mm)
Net Weight
0.20 lb(US) (0.09 kg)
Immunity to microbreaks
10 ms
Electromagnetic compatibility
Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1<br />Immunity for industrial environments conforming to IEC 61000-6-2<br />Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3<br />Emission standard for industrial environments conforming to IEC 61000-6-4<br />Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2<br />Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3<br />Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4<br />Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4<br />Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5<br />Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5<br />Conducted and radiated emissions class B group 1 conforming to CISPR 11<br />Conducted and radiated emissions class B conforming to CISPR 22
Standards
IEC 60255-1
Product Certifications
CE<br />EAC<br />RCM<br />GL<br />CSA<br />UL<br />CCC
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient air temperature for operation
-4…122 °F (-20…50 °C) 60 Hz<br />-4…140 °F (-20…60 °C) 50 Hz AC/DC
Relative humidity
93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30
Vibration resistance
0.075 mm 10…58.1 Hz) not in operation IEC 60068-2-6<br />1 gn 10…58.1 Hz) not in operation IEC 60068-2-6<br />0.035 mm 58.1…150 Hz) in operation IEC 60068-2-6<br />0.5 gn 58.1…150 Hz) in operation IEC 60068-2-6
Shock resistance
15 gn 11 ms) not in operation IEC 60068-2-27<br />5 gn 11 ms) in operation IEC 60068-2-27
IP degree of protection
IP20 IEC 60529 terminals)<br />IP40 IEC 60529 housing)<br />IP50 IEC 60529 front panel)
Pollution degree
3 IEC 60664-1<br />3 UL 508
Dielectric test voltage
2.5 kV AC 50 Hz, 1 min IEC 60255-27

Specifications may be subject to change without notice