Product Model
RM35JA32MW

Selling Points
- 1High-Performance Current Control: The RM35JA32MW control relay offers precise current monitoring with 2CO contacts and a 5A rating.
- 2Versatile Voltage Compatibility: Compatible with 24-240VAC/DC, making it suitable for various electrical applications.
- 3Over/Undercurrent Detection: Detects both overcurrent and undercurrent conditions, ensuring safe operation.
- 4Durable Construction: Built with self-extinguishing plastic housing for long-lasting performance.
- 5Easy Installation: Designed for DIN rail mounting with screw terminals, simplifying installation processes.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Harmony Control Relays | Relay Type | Current control relay |
Product or Component Type | Current control relay | Relay name | RM35JA |
Relay monitored parameters | Overcurrent or undercurrent detection | time delay | Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault<br />Adjustable 1...20 s, 0 + 10 % Ti- inhibition time delay upon startup |
Switching capacity in VA | 1250 VA | Minimum switching current | 10 mA 5 V DC |
Maximum switching current | 5 A AC/DC | Maximum power consumption in VA | 3.5 VA AC |
Measurement range | 150 mA...15 A current AC/DC | Utilisation category | AC-12 IEC 60947-5-1<br />AC-13 IEC 60947-5-1<br />AC-14 IEC 60947-5-1<br />AC-15 IEC 60947-5-1<br />DC-12 IEC 60947-5-1<br />DC-13 IEC 60947-5-1<br />DC-14 IEC 60947-5-1 |
Contacts type and composition | 2 C/O | Reset time | 1500 ms time delay |
Maximum switching voltage | 250 V AC/DC | Supply voltage limits | 20.4…264 V AC/DC |
operating voltage tolerance | - 15 % + 10 % Un | Maximum power consumption in W | 0.6 W DC |
Control circuit frequency | 40...70 Hz +/- 10 % | Resistance across terminals | 0.005 Ohm E3-M terminals<br />0.015 Ohm E2-M terminals<br />0.05 Ohm E1-M terminals |
Output contacts | 2 C/O | Nominal output current | 5 A |
Maximum measuring cycle | 30 ms measurement cycle as true rms value | Hysteresis | 5…50 % threshold setting |
delay at power up | 0.3 s | Measurement accuracy | +/- 10 % of the full scale value |
Repeat accuracy | +/- 0.5 % input and measurement circuit<br />+/- 2 % time delay | Measurement error | 0.05 %/°C with temperature variation<br />1 by volt over the whole range with voltage variation |
Polarity | No DC | Threshold setting | 10...100 % |
marking | CE : EMC 89/336/EEC<br />CE : 73/23/EEC | Overvoltage category | III IEC 60664-1 |
Insulation resistance | > 500 MOhm 500 V DC between supply and relay output IEC 60255-5<br />> 500 MOhm 500 V DC between measurement and relay output IEC 60664-1<br />> 1 MOhm 500 V DC between supply and measurement IEC 60255-5<br />> 500 MOhm 500 V DC between supply and relay output IEC 60664-1<br />> 500 MOhm 500 V DC between measurement and relay output IEC 60255-5<br />> 1 MOhm 500 V DC between supply and measurement IEC 60664-1 | [Ui] rated insulation voltage | 250 V IEC 60664-1 |
Operating position | Any position without derating | Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end<br />Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end<br />Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end<br />Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end |
Tightening torque | 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1 | Housing material | Self-extinguishing plastic |
Local signalling | for power ON LED (green)<br /> for relay ON LED (yellow) | Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
Electrical durability | 100000 cycles | Mechanical durability | 30000000 cycles |
Operating rate | <= 360 operations/hour full load | [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
Safety reliability data | MTTFd = 296.8 years<br />B10d = 270000 | Contacts material | Cadmium free |
Width | 1.4 in (35 mm) | Control Type | Without test button |
Net Weight | 0.29 lb(US) (0.13 kg) | Immunity to microbreaks | 50 ms |
Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4<br />Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3<br />Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 | Standards | IEC 60255-6 |
Product Certifications | GL<br />UL<br />GOST<br />C-tick<br />CSA | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Ambient air temperature for operation | -4…122 °F (-20…50 °C) | Relative humidity | 95 % 131 °F (55 °C) IEC 60068-2-30 |
Vibration resistance | 0.35 mm 5…57.6 Hz)IEC 60068-2-6<br />1 gn 57.6…150 Hz)IEC 60255-21-1 | Shock resistance | 15 gn 11 ms IEC 60255-21-1 |
IP degree of protection | IP20 IEC 60529 terminals)<br />IP30 IEC 60529 casing) | Pollution degree | 3 IEC 60664-1 |
Dielectric test voltage | 2 kV AC 50 Hz, 1 min IEC 60255-5<br />2 kV AC 50 Hz, 1 min IEC 60664-1 | Non-dissipating shock wave | 4 kV IEC 60255-5<br />4 kV IEC 60664-1<br />4 kV IEC 61000-4-5 |
Specifications may be subject to change without notice