schneider RM4UA31MW

Selling Points

  • 1±5% switching threshold drift and ±10% time delay accuracy ensure reliable measurements.
  • 2Measures 0.05–5 V AC/DC and 24–240 V AC/DC, covering a wide range of industrial needs.
  • 3Hysteresis adjustable from 5–30% of the voltage threshold setting for customizable response times.
  • 4Dimensions are 0.37 inches (0.168 mm) wide, making it suitable for space-constrained applications.
  • 5Designed for continuous operation in harsh industrial environments with a maximum switching voltage of 440 V AC.
Product Details
RM4UA31MW
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony Relay
Relay Type
Voltage measurement relay
Product or Component Type
Industrial measurement and control relays
Relay name
RM4U
Relay monitored parameters
Overvoltage or undervoltage detection
time delay
Adjustable 0.05...30 s
Maximum switching voltage
440 V AC
operating voltage tolerance
0.85...1.1 Uc
Power consumption in VA
1.5…3.3 VA AC
Maximum power consumption in W
1.2 W DC
Output contacts
2 C/O
Hysteresis
5…30 % adjustable voltage threshold setting
Internal input resistance
71000 Ohm<br />43000 Ohm<br />6600 Ohm
Permissible continuous overload
80 V<br />20 V<br />60 V
Permissible non repetitive overload
100 A <= 1 s<br />25 A <= 1 s<br />80 A <= 1 s
Switching threshold drift
<= 0.06 % per degree centigrade depending permissible ambient air temperature<br /><= 0.5 % within the supply voltage range (0.85...1.1 Un)
Setting accuracy of time delay
10 P
Time delay drift
<= 0.07 % per degree centigrade depending on the rated operational temperature<br /><= 0.5 % within the supply voltage range (0.85...1.1 Un)
Quality labels
CE
Setting accuracy of the switching threshold
+/-5 %
Operating position
Any position without derating
Overvoltage category
III IEC 60664-1
[Ui] rated insulation voltage
500 V IEC
Supply disconnection value
> 0.1 Uc
Connections - terminals
Screw terminals, 2 x 1.5 mm²flexible with cable end<br />Screw terminals, 2 x 2.5 mm²flexible without cable end
[Ie] rated operational current
2 A 158 °F (70 °C) 24 V DC-13 IEC 60947-5-1/1991<br />2 A 158 °F (70 °C) 24 V DC-13 VDE 0660<br />3 A 158 °F (70 °C) 115 V AC-15 IEC 60947-5-1/1991<br />3 A 158 °F (70 °C) 115 V AC-15 VDE 0660<br />3 A 158 °F (70 °C) 24 V AC-15 IEC 60947-5-1/1991<br />3 A 158 °F (70 °C) 24 V AC-15 VDE 0660<br />3 A 158 °F (70 °C) 250 V AC-15 IEC 60947-5-1/1991<br />3 A 158 °F (70 °C) 250 V AC-15 VDE 0660<br />0.1 A 158 °F (70 °C) 250 V DC-13 IEC 60947-5-1/1991<br />0.1 A 158 °F (70 °C) 250 V DC-13 VDE 0660<br />0.3 A 158 °F (70 °C) 115 V DC-13 IEC 60947-5-1/1991<br />0.3 A 158 °F (70 °C) 115 V DC-13 VDE 0660
Tightening torque
5.3…9.7 lbf.in (0.6…1.1 N.m)
Mechanical durability
30000000 cycles
[Ith] conventional free air thermal current
8 A
Switching capacity in mA
10 mA 12 V
Contacts material
90/10 silver nickel contacts
Width
0.9 in (22.5 mm)
Net Weight
0.18 lb(US) (0.08 kg)
Electromagnetic compatibility
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2<br />Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Ambient air temperature for operation
-4…149 °F (-20…65 °C)
Vibration resistance
0.35 ms 10…55 Hz)IEC 60068-2-6
Shock resistance
15 gn 11 ms IEC 60068-2-27
Standards
EN/IEC 60255-6
Product Certifications
GL<br />UL<br />CSA
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative humidity
15…85 % 3K3 IEC 60721-3-3
IP degree of protection
IP20 IEC 60529 terminals)<br />IP50 IEC 60529 casing)
Pollution degree
3 IEC 60664-1
Directives
73/23/EEC - low voltage directive<br />89/336/EEC - electromagnetic compatibility
Resistance to electrostatic discharge
6 kV contact IEC 61000-4-2 level 3<br />8 kV air IEC 61000-4-2 level 3
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3 level 3
Resistance to fast transients
2 kV IEC 61000-4-4 level 3
Protection against electric shocks
2 kV level 3 IEC 61000-4-5
Disturbance radiated/conducted
CISPR 22 - class A<br />CISPR 11 group 1 - class A
Dielectric test voltage
2.5 kV
Non-dissipating shock wave
4.8 kV

Specifications may be subject to change without notice