  • 1High-performance power distribution for mission-critical applications.
  • 2Robust design with enhanced reliability and durability.
  • 3Compact and space-efficient design for easy installation.
  • 4Advanced thermal management for optimal performance.
  • 5Compatible with a wide range of electrical systems.
Product Details
RXM2LB1BD
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony Electromechanical Relays
Coil interference suppression
Without
Series name
Miniature
Product or Component Type
Plug-in relay
Device short name
RXM
Contacts type and composition
2 C/O
[Ithe] conventional enclosed thermal current
5 A -40…131 °F (-40…55 °C)
Contact operation
Standard
[Uc] control circuit voltage
24 V DC
Status LED
Without
Control Type
Without push-button
[Uimp] rated impulse withstand voltage
4 kV 1.2/50 µs IEC 61810-7
[Ie] rated operational current
5 A AC-1/DC-1) NO IEC<br />2.5 A AC-1/DC-1) NC IEC<br />1 A 28 V DC-13) NO
Minimum switching capacity
25 mW subject to switching frequency, environment or expected reliability level etc
Operating time
20 ms between coil de-energisation and making of the Off-delay contact<br />20 ms between coil energisation and making of the On-delay contact
CAD overall width
0.8 in (21 mm)
CAD overall height
1.06 in (27 mm)
CAD overall depth
1.8 in (46 mm)
Minimum switching current
5 mA subject to switching frequency, environment or expected reliability level etc
Minimum switching voltage
5 V subject to switching frequency, environment or expected reliability level etc
Rated operational voltage limits
19.2...26.4 V DC
[Ui] rated insulation voltage
250 V IEC
Maximum switching voltage
250 V AC<br />28 V DC
Drop-out voltage threshold
>= 0.1 Uc DC
Load current
5 A 250 V AC<br />5 A 28 V DC
Maximum switching capacity
1250 VA AC<br />140 W DC
Average resistance
640 Ohm at 73 °F (23 °C) +/- 10 %
Average coil consumption
0.9 W, DC
Mechanical durability
10000000 cycles
Electrical durability
100000 cycles for resistive load<br />50000 cycles, 1 A at 28 V, DC-13 NO
Safety reliability data
B10d = 100000
Operating rate
<= 1200 cycles/hour under load<br /><= 18000 cycles/hour no-load
Utilisation coefficient
20 %
Dielectric strength
2000 V AC between coil and contact with basic insulation<br />2000 V AC between poles with basic insulation<br />1000 V AC between contacts with micro disconnection
Protection category
RT I
Pollution degree
3
Operating position
Any position
Test levels
Level A group mounting
Sale per indivisible quantity
10
Contacts material
Silver alloy (Ag/Ni)
Net Weight
0.071 lb(US) (0.032 kg)
IP degree of protection
IP40 conforming to IEC 60529
Standards
CE<br />IEC 61810-1 (iss. 2)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Vibration resistance
3 gn +/- 1 mm 10…50 Hz)operating IEC 60068-2-6<br />6 gn +/- 1 mm 10…50 Hz)not operating IEC 60068-2-6
Shock resistance
30 gnnot operating IEC 60068-2-27<br />10 gnin operation IEC 60068-2-27