RXM4GB3B7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony Relay
Series name
Miniature
Product or Component Type
Plug-in relay
Device short name
RXM
Contacts type and composition
4 C/O
[Uc] control circuit voltage
24 V AC 50/60 Hz
[Ithe] conventional enclosed thermal current
3 A -40…131 °F (-40…55 °C)
Status LED
With
Control Type
Without lockable test button
Utilisation coefficient
20 %
Shape of pin
Flat
[Ui] rated insulation voltage
250 V IEC<br />300 V CSA<br />300 V UL
[Uimp] rated impulse withstand voltage
2.5 kV 1.2/50 µs
Contacts material
Gold plated bifurcated silver
[Ie] rated operational current
2 A 28 V DC) NO IEC<br />2 A 250 V AC) NO IEC<br />1 A 28 V DC) NC IEC<br />1 A 250 V AC) NC IEC<br />3 A 28 V DC) UL<br />3 A 277 V AC) UL
Maximum switching voltage
250 V IEC
resistive rated load
3 A 250 V AC<br />3 A 28 V DC
Maximum switching capacity
750 VA/84 W
Minimum switching capacity
15 mW 3 mA, 5 V
Operating rate
<= 1200 cycles/hour under load<br /><= 18000 cycles/hour no-load
Mechanical durability
10000000 cycles
Electrical durability
100000 cycles resistive depending on mounting position and working environment
average coil consumption in VA
1.2 60 Hz
Average consumption
1.2 VA 60 Hz
Drop-out voltage threshold
>= 0.15 Uc
operate time
20 ms
release time
20 ms
average coil resistance
180 Ohm 20 °C +/- 15 %
Rated operational voltage limits
19.2...26.4 V AC
Protection category
RT I
Operating position
Any position
Net Weight
0.082 lb(US) (0.037 kg)
Device presentation
Complete product
Dielectric strength
1300 V AC between contacts with micro disconnection<br />2000 V AC between coil and contact<br />2000 V AC between poles
Product Certifications
UL<br />Lloyd's<br />CE<br />CSA<br />GOST<br />IECEE CB Scheme
Standards
IEC 61810-1<br />UL 508<br />CSA C22.2 No 14
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Ambient air temperature for operation
-40…131 °F (-40…55 °C)
Vibration resistance
3 gn +/- 1 mm 10…150 Hz)5 cycles in operation<br />5 gn +/- 1 mm 10…150 Hz)5 cycles not operating
IP degree of protection
IP40 conforming to IEC 60529
Shock resistance
10 gnin operation<br />30 gnnot operating
Pollution degree
2

Specifications may be subject to change without notice