schneider TM172E28R

Selling Points

  • 1High current output up to 28A for demanding applications.
  • 2Robust construction with durable components for long-lasting performance.
  • 3Compact design for easy integration into industrial systems.
  • 4Wide input voltage range for flexibility in various environments.
  • 5Compliant with international safety standards for reliability and safety.
Product Details
TM172E28R
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon M171/M172
Product or Component Type
Additional I/O module
Product Specific Application
HVAC control
Total inputs/outputs
28
Discrete input number
2<br />4
Discrete output number
3 relay outputs SPST with same common<br />2 relay outputs SPST with same common
Discrete output current
3 A relay SPST
Analogue input number
10 configurable by pair
Analogue output number
2 programmable
Number of port
1 CAN port - screw terminal block
Input/output number
2 analog output<br />6 digital input<br />10 analog input<br />10 digital output
Discrete input logic
2 positive logic (sink) up to 2 kHz<br />4 positive logic (sink)
Discrete input voltage
24 V AC/DC
Discrete input current
2.5 mA AC/DC
input impedance
20 kOhm
Analogue input type
NTC NK103 Beta 3977 temperature probe - 40...137 °C 0.1 °C 10 kOhm at 25 °C)<br />NTC 103AT-2 Beta 3435 temperature probe - 50...110 °C 0.1 °C 10 kOhm at 25 °C)<br /> current 0...20 mA 1 digit < 150 Ohm<br /> current 4...20 mA 1 digit < 150 Ohm<br /> voltage 0...10 V 1 digit > 10 kOhm<br /> voltage 0...5 V 1 digit > 20 kOhm absolute or ratiometric)<br /> impedance 0...1500 hOhm 1 hOhm 10 kOhm<br /> impedance 0...300 daOhm 1 daOhm 2 kOhm<br /> direct input 1 digit Dry contact)<br /> PTC - 55...150 °C 0.1 °C 2 kOhm<br /> Pt 1000 temperature probe - 200...850 °C 0.1 °C 2 kOhm
Measurement accuracy
NTC NK103 - 40...+110 °C +/- 1 °C<br /> NTC NK103 110...137 °C +/- 1.9 °C<br /> NTC 103AT-2 - 50…110 °C +/- 1 °C<br /> PTC - 55...+135 °C +/- 1.1 °C<br /> PTC - 150…135 °C +/- 3.1 °C<br /> Pt 1000 - 200...-100 °C +/- 5 °C<br /> Pt 1000 - 100...-50 °C +/- 3 °C<br /> Pt 1000 - 50...+200 °C +/- 1.5 °C<br /> Pt 1000 200...600 °C +/- 15 °C<br /> Pt 1000 600...850 °C +/- 30 °C<br />0...20 mA 0...4 mA +/- 2 % of full scale +/- 1 digit<br />0...20 mA 4...20 mA +/- 1 % of full scale +/- 1 digit<br />4...20 mA +/- 1 % of full scale +/- 1 digit<br />0...10 V +/- 1 % of full scale +/- 1 digit<br />0...5 V +/- 1 % of full scale +/- 1 digit<br />HOhm 0...700 hOhm +/- 10 hOhm<br />HOhm 700 hOhm...1200 hOhm +/- 25 hOhm<br />HOhm 1200 hOhm...1500 hOhm +/- 60 hOhm<br />DaOhm 0...300 daOhm +/- 2.5 daOhm
Sensor power supply
5 V DC 50 mA<br />24 V DC 125 mA
[Us] rated supply voltage
24 V +/- 10 % AC<br />20...38 V DC
Power consumption in W
24 VA 24 V AC<br />15 W 24 V DC
Realtime clock
Without clock
Display type
Without Display
Overvoltage category
II
Mounting Support
DIN rail<br />Panel mounting with accessory
Width
2.8 in (72 mm)
Height
4.3 in (110 mm)
Depth
2.3 in (59 mm)
Net Weight
0.42 lb(US) (0.19 kg)
Directives
2014/35/EU - low voltage directive<br />2014/30/EU - electromagnetic compatibility
Standards
IEC 61000-4-4<br />EN 60068-2-27<br />CSA E60730-2-9<br />IEC 61000-4-11<br />CAN/CSA-E60730-1<br />UL 60730-2-9<br />EN 60730-2-9<br />EN 60730-1<br />IEC 61000-4-5<br />IEC 61000-4-3<br />EN 60068-2-6 Fc<br />IEC 61000-4-2<br />UL94 (material V0)
Product Certifications
cURus<br />EAC<br />CE<br />RCM<br />CSA
Ambient air temperature for operation
-4…149 °F (-20…65 °C) UL 60730-1
Ambient Air Temperature for Storage
-22…158 °F (-30…70 °C)
Relative humidity
5…95 % non-condensing
IP degree of protection
IP20
Pollution degree
2

Specifications may be subject to change without notice