schneider TM3TI4DG

Selling Points

  • 1The TM3TI4DG module offers four analog input channels for precise temperature measurement.
  • 2Equipped with a removable spring terminal block for easy and secure connections.
  • 3Operates on a reliable 24V DC power supply, ensuring stable performance in industrial environments.
  • 4Provides high-resolution measurements with up to 16-bit resolution, ensuring accurate temperature readings.
  • 5Designed for differential temperature inputs, enhancing channel isolation and measurement accuracy.
Product Details
TM3TI4DG
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon TM3
Product or Component Type
Analog input module
Range Compatibility
Modicon M221<br />Modicon M241<br />Modicon M251<br />Modicon M262
Analogue input number
4
Analogue input type
thermocouple - 200...1000 °C thermocouple J<br /> thermocouple - 200...1300 °C thermocouple K<br /> thermocouple 0...1760 °C thermocouple R<br /> thermocouple 0...1760 °C thermocouple S<br /> thermocouple 0...1820 °C thermocouple B<br /> thermocouple - 200...400 °C thermocouple T<br /> thermocouple - 200...1300 °C thermocouple N<br /> thermocouple - 200...800 °C thermocouple E<br /> thermocouple 0...2315 °C thermocouple C
Analogue input resolution
16 bits<br />15 bits + sign
Permissible continuous overload
13 V voltage<br />40 mA current
Input impedance
>= 1 MOhm thermocouple
LSB value
0.1 °C thermocouple
Conversion time
100 ms + 100 ms per channel + 1 controller cycle time thermocouple
Sampling duration
100 ms thermocouple
Absolute accuracy error
+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple C 0...2315 °C<br />+/- 6 °C at 77 °F (25 °C) for thermocouple R, S 0...200 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple R, S 200...1760 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple B 300...1820 °C<br />+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple K - 200...0 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple K 0...1300 °C<br />+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple J - 200...0 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple J 0...1000 °C<br />+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple E - 200...0 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple E 0...800 °C<br />+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple T - 200...0 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple T 0...400 °C<br />+/- 0.4 % of full scale at 77 °F (25 °C) for thermocouple N - 200...0 °C<br />+/- 0.2 % of full scale at 77 °F (25 °C) for thermocouple N 0...1300 °C
Temperature Drift
+/- 0.01 %FS/°C
Repeat accuracy
+/-0.5 %FS
Non-linearity
+/- 0.2 %FS
Cross talk
<= 1 LSB
[Us] rated supply voltage
24 V DC
Supply voltage limits
20.4…28.8 V
Type of cable
Twisted shielded pairs cable <98.4 ft (30 m) input
Current consumption
45 mA 5 V DC via bus connector<br />50 mA 5 V DC via bus connector<br />35 mA 24 V DC via external supply<br />40 mA 24 V DC via external supply
Local signalling
for PWR 1 LED (green)
Electrical connection
10 x 1.5 mm² removable spring terminal block pitch 3.81 mm for inputs and supply<br />10 x 1.5 mm² removable spring terminal block pitch 3.81 mm for inputs
Insulation
Between input and supply 1500 V AC<br />Between input and internal logic 500 V AC
marking
CE
Surge withstand
1 kV power supply common mode IEC 61000-4-5<br />0.5 kV power supply differential mode IEC 61000-4-5<br />1 kV input common mode IEC 61000-4-5
Mounting support
Top hat type TH35-15 rail IEC 60715<br />Top hat type TH35-7.5 rail IEC 60715<br /> plate or panel with fixing kit
Height
3.5 in (90 mm)
Depth
2.8 in (70 mm)
Width
0.9 in (23.6 mm)
Net Weight
0.24 lb(US) (0.11 kg)
Standards
IEC 61131-2
Product Certifications
CE<br />UKCA<br />RCM<br />EAC<br />cULus<br />cULus HazLoc
Resistance to electrostatic discharge
8 kV in air IEC 61000-4-2<br />4 kV on contact IEC 61000-4-2
Resistance to electromagnetic fields
9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3<br />2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3<br />0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3
Resistance to fast transients
1 kV IEC 61000-4-4 I/O)
Resistance to conducted disturbances
10 V 0.15...80 MHz IEC 61000-4-6<br />3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission
Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz IEC 55011<br />Radiated emissions 47 dBμV/m QP class A 10 m)230…1000 MHz IEC 55011
Immunity to microbreaks
10 ms
Ambient Air Temperature for Operation
14…131 °F (-10…55 °C) horizontal installation<br />14…95 °F (-10…35 °C) vertical installation
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative humidity
10…95 %, without condensation in operation)<br />10…95 %, without condensation in storage)
IP Degree of Protection
IP20
Pollution degree
2
Operating altitude
0...6561.68 ft (0...2000 m)
Storage altitude
0.0000000000…9842.5 ft (0…3000 m)
Vibration resistance
3.5 mm 5…8.4 Hz DIN rail<br />3 gn 8.4…150 Hz DIN rail
Shock resistance
15 gn 11 ms

Specifications may be subject to change without notice