schneider TM5SBET7

Selling Points

  • 1Flexible and scalable I/O configuration.
  • 2Embedded diagnostics for local and distant supervision.
  • 3Hot swapping of I/O modules for easy maintenance.
  • 4Cabling simplicity with spring terminals and removable terminal blocks.
  • 5Saves engineering time with streamlined setup and diagnostics.
Product Details
TM5SBET7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon TM5
Product or Component Type
Remote transmitter module
Product Specific Application
Communication between remote I/O
Range Compatibility
Modicon M258<br />Modicon LMC058
Product Compatibility
Motion controller<br />Logic controller
[Us] rated supply voltage
24 V DC - 15...20 %
Color
White
Bus length
8202.10 ft (2500 m)
Maximum cable distance between devices
328.08 ft (100 m)
Current consumption
25 mA 24 V DC input/output<br />100 mA 5 V DC bus
Maximum power dissipation in W
1.1 W
Local signalling
1 LED green power supply<br />1 LED red power supply<br />1 LED yellow communication data bus
Supply
Included for IP67 extension modules
marking
CE
Net Weight
0.055 lb(US) (0.025 kg)
Standards
UL 508<br />CSA C22.2 No 142<br />IEC 61131-2<br />CSA C22.2 No 213
Product Certifications
CSA<br />GOST-R<br />cULus<br />C-tick
Ambient air temperature for operation
32…122 °F (0…50 °C) vertical installation)<br />32…131 °F (0…55 °C) without derating horizontal installation)<br />32…140 °F (0…60 °C) with derating factor horizontal installation)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative Humidity
5…95 % without condensation
IP degree of protection
IP20IEC 61131-2<br />IP67
Pollution degree
2 IEC 60664
Operating altitude
0...6561.68 ft (0...2000 m)
Storage altitude
0.0000000000…9842.5 ft (0…3000 m)
Vibration resistance
1 gn 8.4…150 Hz DIN rail<br />3.5 mm 5…8.4 Hz DIN rail
Shock resistance
15 gn 11 ms
Resistance to electrostatic discharge
4 kV on contact IEC 61000-4-2<br />8 kV in air IEC 61000-4-2
Resistance to electromagnetic fields
0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3<br />9.1 V/m (10 V/m) 80...2000 MHz IEC 61000-4-3
Resistance to fast transients
1 kV IEC 61000-4-4 I/O)<br />1 kV IEC 61000-4-4 shielded cable)<br />2 kV IEC 61000-4-4 power lines)
Surge withstand
0.5 kV differential mode IEC 61000-4-5<br />1 kV common mode IEC 61000-4-5
Electromagnetic compatibility
EN/IEC 61000-4-6
Disturbance radiated/conducted
CISPR 11

Specifications may be subject to change without notice