schneider TM5SDO2R

Selling Points

  • 1Flexible and Scalable I/O Configuration: Easily integrate into complex machines with a flexible and scalable I/O configuration.
  • 2Embedded Diagnostics: Enjoy embedded diagnostics for local and distant supervision, ensuring efficient monitoring.
  • 3Hot Swapping of I/O Modules: Simplify maintenance with hot swapping of I/O modules, reducing downtime.
  • 4Cabling Simplicity: Utilize spring terminals and removable terminal blocks for easy cabling setup.
  • 5High-Performance Reliability: Achieve high-performance reliability with a maximum power dissipation of 2.45W and 10ms conversion rate.
Product Details
TM5SDO2R
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon TM5
Product or Component Type
Discrete output module
Discrete output number
2
Discrete output type
Relay
Range Compatibility
PacDrive LMC motion controller<br />Modicon LMC058<br />Modicon M258
Product Compatibility
Logic controller<br />PacDrive LMC Pro<br />Motion controller<br />PacDrive LMC Pro 2<br />PacDrive LMC Eco
Output voltage
230 V AC<br />30 V DC
Output voltage limits
184...276 V AC<br />24...36 V DC
Discrete output function
2 C/O
Current per channel
5 A
Maximum current per output common
10 A
Color
Black
Response time
<= 10 ms from state 0 to state 1 output<br /><= 10 ms from state 1 to state 0 output
Protection Type
Reverse polarity protection<br />Without overload protection<br />Without short-circuit protection
Isolation
No insulation between channels<br />500 Vrms AC insulation between channel and bus
Current consumption
90 mA 5 V DC bus
Maximum power dissipation in W
2.45 W
marking
CE
Net Weight
0.055 lb(US) (0.025 kg)
Standards
IEC 61131-2<br />UL 508<br />CSA C22.2 No 213<br />CSA C22.2 No 142
Product Certifications
GOST-R<br />CSA<br />C-tick<br />cULus
Ambient air temperature for operation
14…131 °F (-10…55 °C) without derating horizontal installation)<br />14…140 °F (-10…60 °C) with derating factor horizontal installation)<br />14…122 °F (-10…50 °C) vertical installation)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Relative Humidity
5…95 % without condensation
IP degree of protection
IP20IEC 61131-2
Pollution degree
2 IEC 60664
Operating altitude
0...6561.68 ft (0...2000 m)
Storage altitude
0.0000000000…9842.5 ft (0…3000 m)
Vibration resistance
1 gn 8.4…150 Hz DIN rail<br />3.5 mm 5…8.4 Hz DIN rail
Shock resistance
15 gn 11 ms
Electromagnetic compatibility
Electrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2<br />Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2<br />Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz IEC 61000-4-3<br />Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3<br />Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4<br />Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4<br />Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4<br />1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5<br />1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5<br />Conducted RF disturbances IEC 61000-4-6<br />Conducted and radiated emissions CISPR 11

Specifications may be subject to change without notice