Product Model

TM5SE2IC01024

In Stock
Last updated: 2025/4/23
schneider TM5SE2IC01024

Selling Points

  • 1High-Performance Counter Module: The TM5SE2IC01024 provides 2 HSC incremental encoder inputs with a high counting frequency of 100 kHz.
  • 2Flexible I/O Configuration: Designed for flexible and scalable I/O configurations, suitable for complex automation solutions.
  • 324 VDC Power Supply: Equipped with a 24 VDC power supply for the encoder, ensuring reliable operation.
  • 4IP20 Rated and Insulated: Meets IP20 standards with insulation between channels and bus at 500Vrms AC.
  • 5Certified for Safety Standards: Compliant with GOST-R, C-Tick, cULus, and CSA standards, ensuring safety in industrial applications.
Product Details
TM5SE2IC01024
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon TM5
Product or Component Type
Counter module
Product Specific Application
Period measurement<br />Frequency generator<br />Frequency meter<br />Downcounting<br />Upcounting<br />Axis following with encoder
Function of module
2 x 24 V DC auxiliary inputs<br />24 V DC encoder power supply
Discrete input number
2
Counting frequency
100 kHz
Encoder type
2 incremental encoders
Range Compatibility
Modicon LMC058<br />Modicon M258
Product Compatibility
Logic controller<br />Motion controller
Counter inputs resolution
16 bits/32 bits
Maximum cycle time
2 ms
Input compatibility
2 incremental encoders (24 V)
Isolation
500 Vrms AC insulation between channel and bus
Discrete input logic
Sink
Discrete input voltage
24 V DC
Discrete input current
1.3 mA 24 V
Input resistance
18.4 kOhm
Current consumption
2 mA 5 V DC bus<br />63 mA 24 V DC input/output
Maximum power dissipation in W
1.51 W
marking
CE
Net Weight
0.055 lb(US) (0.025 kg)
Standards
UL 508<br />CSA C22.2 No 142<br />CSA C22.2 No 213<br />IEC 61131-2
Product Certifications
GOST-R<br />CSA<br />C-tick<br />cULus
Ambient air temperature for operation
32…131 °F (0…55 °C) without derating horizontal installation)<br />32…140 °F (0…60 °C) with derating factor horizontal installation)<br />32…122 °F (0…50 °C) vertical installation)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative humidity
5…95 % without condensation
IP degree of protection
IP20IEC 61131-2
Pollution degree
2 IEC 60664
Operating altitude
0...6561.68 ft (0...2000 m)
Storage altitude
0.0000000000…9842.5 ft (0…3000 m)
Vibration resistance
1 gn 8.4…150 Hz DIN rail<br />3.5 mm 5…8.4 Hz DIN rail
Shock resistance
15 gn 11 ms
Resistance to electrostatic discharge
4 kV on contact IEC 61000-4-2<br />8 kV in air IEC 61000-4-2
Resistance to electromagnetic fields
0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3<br />9.1 V/m (10 V/m) 80...2000 MHz IEC 61000-4-3
Resistance to fast transients
1 kV IEC 61000-4-4 I/O)<br />1 kV IEC 61000-4-4 shielded cable)<br />2 kV IEC 61000-4-4 power lines)
Surge withstand
0.5 kV differential mode IEC 61000-4-5<br />1 kV common mode IEC 61000-4-5
Electromagnetic compatibility
EN/IEC 61000-4-6
Disturbance radiated/conducted
CISPR 11

Specifications may be subject to change without notice