Product Model
TM5SPS10FS

Selling Points
- 1Safe Power Distribution: Ensures safe power-off state to non-safety-related I/O modules.
- 2High Reliability: Supports up to 10A output current for reliable I/O power supply.
- 3Integrated Protection: Equipped with over-current protection and inductive load resistance.
- 4Flexible Configuration: Compatible with Modicon TM5CSLC safety logic controller and other Modicon systems.
- 5Comprehensive Safety Features: Meets Category 4 / PL e safety standards according to EN ISO 13849-1.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Modicon TM5 | Product or Component Type | Power distribution module |
Product Specific Application | Supply 24 V DC I/O modules | Range Compatibility | Modicon M258<br />Modicon LMC058 |
Product Compatibility | Motion controller<br />Logic controller | [Us] rated supply voltage | 24 V |
Network type | DC | current supplied | 10 A I/O power segment |
Maximum power dissipation in W | 0.8 W | Color | Red |
Short-circuit protection | 10 A external fuse | Current consumption | <= 25 mA 24 V DC |
marking | CE | Net Weight | 0.134 lb(US) (0.061 kg) |
Standards | IEC 61131-2<br />UL 508<br />CSA C22.2 No 142<br />CSA C22.2 No 213 | Product Certifications | cULus<br />CSA |
Ambient air temperature for operation | 14…131 °F (-10…55 °C) without derating horizontal installation)<br />131…140 °F (55…60 °C) with derating factor horizontal installation)<br />14…122 °F (-10…50 °C) vertical installation) | Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Relative humidity | 5…95 % without condensation | Operating altitude | 0...6561.68 ft (0...2000 m) |
Storage altitude | 0.0000000000…9842.5 ft (0…3000 m) | Vibration resistance | 1 gn 8.4…150 Hz DIN rail<br />3.5 mm 5…8.4 Hz DIN rail |
Shock resistance | 15 gn 11 ms | Resistance to electrostatic discharge | 4 kV on contact EN/IEC 61000-4-2<br />8 kV in air EN/IEC 61000-4-2 |
Resistance to electromagnetic fields | 0.9 V/m (1 V/m) 2...2.7 GHz EN/IEC 61000-4-3<br />9.1 V/m (10 V/m) 80...2000 MHz EN/IEC 61000-4-3 | Resistance to fast transients | 1 kV EN/IEC 61000-4-4 I/O)<br />1 kV EN/IEC 61000-4-4 shielded cable)<br />2 kV EN/IEC 61000-4-4 power lines) |
Surge withstand | 0.5 kV differential mode EN/IEC 61000-4-5<br />1 kV common mode EN/IEC 61000-4-5 | Electromagnetic compatibility | EN/IEC 61000-4-6 |
Disturbance radiated/conducted | CISPR 11 |
Specifications may be subject to change without notice