Product Model
TSXAEY1614

Selling Points
- 1The TSXAEY1614 delivers 16-bit analog-to-digital conversion, ensuring high-resolution data processing for accurate measurement and control.
- 2Supports B, E, J, K, L, N, R, S, T, and U thermocouple types, making it versatile for various temperature measurement applications.
- 3Operates with a nominal read cycle time of 70 milliseconds per channel, providing fast and reliable data acquisition.
- 4Offers 1000 Vrms isolation between channels and the bus and between channels and the ground, ensuring safe operation in high-voltage environments.
- 5Consumes 300 mA at 5 V DC, making it energy-efficient for continuous use in industrial settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Modicon Premium Automation platform | Product or Component Type | Analog input module |
Analogue input number | 16 | Analogue input type | Thermocouple thermocouple B<br />Thermocouple thermocouple E<br />Thermocouple thermocouple J<br />Thermocouple thermocouple K<br />Thermocouple thermocouple L<br />Thermocouple thermocouple N<br />Thermocouple thermocouple R<br />Thermocouple thermocouple S<br />Thermocouple thermocouple T<br />Thermocouple thermocouple U<br />Voltage +/- 80 mV |
Analog/digital conversion | 16 bits | Nominal read cycle time | 70 ms per channel |
Measurement error | 0.8 °C thermocouple E 25 °C<br />0.9 °C thermocouple J 25 °C<br />0.9 °C thermocouple L 25 °C<br />1 °C thermocouple K 25 °C<br />1 °C thermocouple T 25 °C<br />1 °C thermocouple U 25 °C<br />1.1 °C thermocouple N 25 °C<br />1.2 °C thermocouple E 0...60 °C<br />1.3 °C thermocouple T 0...60 °C<br />1.3 °C thermocouple U 0...60 °C<br />1.4 °C thermocouple J 0...60 °C<br />1.4 °C thermocouple L 0...60 °C<br />1.6 °C thermocouple K 0...60 °C<br />1.7 °C thermocouple N 0...60 °C<br />2.1 °C thermocouple R 25 °C<br />2.2 °C thermocouple S 25 °C<br />2.4 °C thermocouple R 0...60 °C<br />2.5 °C thermocouple B 25 °C<br />3.7 °C thermocouple S 0...60 °C<br />4 °C thermocouple B 0...60 °C | Isolation between channels and bus | 1000 Vrms |
Isolation between channels and ground | 1000 Vrms | Common mode between channels | 250 V AC or 280 V AC |
Common mode between channels and earth | 250 V DC | Input overvoltage protection | -15…15 V at state 0 250 Ohm<br />-30…30 V at state 1 250 Ohm |
Electrical connection | 2 connectors SUB-D 25 | Overcurrent | -30…30 mA at state 1 250 kOhm |
marking | CE | Current consumption | 300 mA 5 V DC |
Module format | Standard | Net Weight | 0.77 lb(US) (0.35 kg) |
Standards | NFC 42-330<br />IEC 1131<br />DIN 43710<br />IEC 751<br />DIN 43760<br />IEC 584 | Product Certifications | DNV<br />RMRS<br />LR<br />ABS<br />RINA<br />BV<br />GL |
Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) | Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Relative Humidity | 10…95 % without condensation for operation<br />5…95 % without condensation for storage | Operating altitude | 0...6561.68 ft (0...2000 m) |
Protective treatment | TC | IP Degree of Protection | IP20 |
Pollution degree | 2 |
Specifications may be subject to change without notice