Product Model

TSXAEY1614

In Stock
Last updated: 2025/4/21
schneider TSXAEY1614

Selling Points

  • 1The TSXAEY1614 delivers 16-bit analog-to-digital conversion, ensuring high-resolution data processing for accurate measurement and control.
  • 2Supports B, E, J, K, L, N, R, S, T, and U thermocouple types, making it versatile for various temperature measurement applications.
  • 3Operates with a nominal read cycle time of 70 milliseconds per channel, providing fast and reliable data acquisition.
  • 4Offers 1000 Vrms isolation between channels and the bus and between channels and the ground, ensuring safe operation in high-voltage environments.
  • 5Consumes 300 mA at 5 V DC, making it energy-efficient for continuous use in industrial settings.
Product Details
TSXAEY1614
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon Premium Automation platform
Product or Component Type
Analog input module
Analogue input number
16
Analogue input type
Thermocouple thermocouple B<br />Thermocouple thermocouple E<br />Thermocouple thermocouple J<br />Thermocouple thermocouple K<br />Thermocouple thermocouple L<br />Thermocouple thermocouple N<br />Thermocouple thermocouple R<br />Thermocouple thermocouple S<br />Thermocouple thermocouple T<br />Thermocouple thermocouple U<br />Voltage +/- 80 mV
Analog/digital conversion
16 bits
Nominal read cycle time
70 ms per channel
Measurement error
0.8 °C thermocouple E 25 °C<br />0.9 °C thermocouple J 25 °C<br />0.9 °C thermocouple L 25 °C<br />1 °C thermocouple K 25 °C<br />1 °C thermocouple T 25 °C<br />1 °C thermocouple U 25 °C<br />1.1 °C thermocouple N 25 °C<br />1.2 °C thermocouple E 0...60 °C<br />1.3 °C thermocouple T 0...60 °C<br />1.3 °C thermocouple U 0...60 °C<br />1.4 °C thermocouple J 0...60 °C<br />1.4 °C thermocouple L 0...60 °C<br />1.6 °C thermocouple K 0...60 °C<br />1.7 °C thermocouple N 0...60 °C<br />2.1 °C thermocouple R 25 °C<br />2.2 °C thermocouple S 25 °C<br />2.4 °C thermocouple R 0...60 °C<br />2.5 °C thermocouple B 25 °C<br />3.7 °C thermocouple S 0...60 °C<br />4 °C thermocouple B 0...60 °C
Isolation between channels and bus
1000 Vrms
Isolation between channels and ground
1000 Vrms
Common mode between channels
250 V AC or 280 V AC
Common mode between channels and earth
250 V DC
Input overvoltage protection
-15…15 V at state 0 250 Ohm<br />-30…30 V at state 1 250 Ohm
Electrical connection
2 connectors SUB-D 25
Overcurrent
-30…30 mA at state 1 250 kOhm
marking
CE
Current consumption
300 mA 5 V DC
Module format
Standard
Net Weight
0.77 lb(US) (0.35 kg)
Standards
NFC 42-330<br />IEC 1131<br />DIN 43710<br />IEC 751<br />DIN 43760<br />IEC 584
Product Certifications
DNV<br />RMRS<br />LR<br />ABS<br />RINA<br />BV<br />GL
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative Humidity
10…95 % without condensation for operation<br />5…95 % without condensation for storage
Operating altitude
0...6561.68 ft (0...2000 m)
Protective treatment
TC
IP Degree of Protection
IP20
Pollution degree
2

Specifications may be subject to change without notice