Product Model

TSXSCY21601C

In Stock
Last updated: 2025/4/18
schneider TSXSCY21601C

Selling Points

  • 1High-Performance Communication: Efficiently manage 28 devices with the TSXSCY21601C communication module.
  • 2Modicon Premium Compatibility: Seamlessly integrate with the Modicon Premium Automation platform.
  • 3Unity Pro Software Support: Compatible with Unity Pro software for advanced automation solutions.
  • 4Multiprotocol Support: Handles various protocols for versatile industrial applications.
  • 5Reliable Connectivity: Ensures reliable communication with asynchronous baseband transmission and CRC 16 on each frame.
Product Details
TSXSCY21601C
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon Premium Automation platform
Product or Component Type
Communication module
Software Designation
Unity Pro
Structure type
Heterogeneous industrial bus
Product Compatibility
Premium<br />Atrium
Method of access
Master/slave type
Integrated connection type
1 serial link 1 SUB-D 25<br />1 slot for PCMCIA type III card
communication port protocol
Multiprotocol
Communication port support
RS485 isolated
Mode of Transmission
Asynchronous in baseband
Transmission frame
RTU/ASCII
Transmission Rate
1.2...19.2 kbit/s
Transmission support medium
2 twisted shielded pairs cable
Number of devices
28
Number of addresses
0…97
Bus length
0.0000000000…4265.09 ft (0…1300 m) Modbus
Maximum tap links length
49.2 ft (15 m)
Requests
120 words per request<br />1920 bits per request
Control parameter
One CRC 16 on each frame
Monitoring function
Event counters<br />Diagnostic counters
Modbus funtions available
Event connection Modbus master 0C<br />Event connection Modbus slave 0C<br />Event counter Modbus master 0B<br />Event counter Modbus slave 0B<br />Identification Modbus slave 11<br />Slave identification Modbus master 11<br />Write n output bits Modbus slave 0F<br />Write n output words Modbus slave 10<br />Diagnostic Modbus master 08<br />Diagnostic Modbus slave 08<br />Exceptional read status Modbus master 07<br />Exceptional read status Modbus slave 07<br />Read input words Modbus master 04<br />Read n input words Modbus slave 04<br />Write 1 bits or n bits Modbus master 05<br />Write 1 input word Modbus slave 06<br />Write 1 output bit Modbus slave 05<br />Write 1 word or n word Modbus master 06
Local signalling
for communication (CH0) 1 LED<br /> for internal fault, module failure (ERR) 1 LED<br /> for module operating (RUN) 1 LED
Current consumption
350 mA 5 V DC
Module format
Standard
Net Weight
0.79 lb(US) (0.36 kg)
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative Humidity
5…95 % without condensation
Operating altitude
<= 6561.68 ft (2000 m)

Specifications may be subject to change without notice