Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Modicon Premium Automation platform | Product or Component Type | Communication module |
Software Designation | Unity Pro | Structure type | Heterogeneous industrial bus |
Product Compatibility | Premium<br />Atrium | Method of access | Master/slave type |
Integrated connection type | 1 serial link 1 SUB-D 25<br />1 slot for PCMCIA type III card | communication port protocol | Multiprotocol |
Communication port support | RS485 isolated | Mode of Transmission | Asynchronous in baseband |
Transmission frame | RTU/ASCII | Transmission Rate | 1.2...19.2 kbit/s |
Transmission support medium | 2 twisted shielded pairs cable | Number of devices | 28 |
Number of addresses | 0…97 | Bus length | 0.0000000000…4265.09 ft (0…1300 m) Modbus |
Maximum tap links length | 49.2 ft (15 m) | Requests | 120 words per request<br />1920 bits per request |
Control parameter | One CRC 16 on each frame | Monitoring function | Event counters<br />Diagnostic counters |
Modbus funtions available | Event connection Modbus master 0C<br />Event connection Modbus slave 0C<br />Event counter Modbus master 0B<br />Event counter Modbus slave 0B<br />Identification Modbus slave 11<br />Slave identification Modbus master 11<br />Write n output bits Modbus slave 0F<br />Write n output words Modbus slave 10<br />Diagnostic Modbus master 08<br />Diagnostic Modbus slave 08<br />Exceptional read status Modbus master 07<br />Exceptional read status Modbus slave 07<br />Read input words Modbus master 04<br />Read n input words Modbus slave 04<br />Write 1 bits or n bits Modbus master 05<br />Write 1 input word Modbus slave 06<br />Write 1 output bit Modbus slave 05<br />Write 1 word or n word Modbus master 06 | Local signalling | for communication (CH0) 1 LED<br /> for internal fault, module failure (ERR) 1 LED<br /> for module operating (RUN) 1 LED |
Current consumption | 350 mA 5 V DC | Module format | Standard |
Net Weight | 0.79 lb(US) (0.36 kg) | Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) | Relative Humidity | 5…95 % without condensation |
Operating altitude | <= 6561.68 ft (2000 m) |