schneider XB4FVG5

Selling Points

  • 1High reliability and durability for continuous operation.
  • 2Compact design with minimal footprint for space-saving installations.
  • 3Wide input voltage range for flexibility in various environments.
  • 4Advanced thermal management for extended lifespan and performance.
  • 5Compliant with international safety standards for secure operation.
Product Details
XB4FVG5
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB4
Product or Component Type
Pilot light
Device short name
XB4F
Bezel material
Chromium plated metal
Fixing collar material
Zamak
Head type
Built-in-flush
Mounting diameter
1.2 in (30.5 mm)
Sale per indivisible quantity
1
Shape of signaling unit head
Round
cap/operator or lens colour
Orange
Operator additional information
With plain lens
Light source
Universal LED
Bulb base
Integral LED
[Us] rated supply voltage
110...120 V AC 50/60 Hz
CAD overall width
1.4 in (36.6 mm)
CAD overall height
1.4 in (36.6 mm)
CAD overall depth
2.1 in (53.6 mm)
Net Weight
0.247 lb(US) (0.112 kg)
Resistance to high pressure washer
1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Device mounting
Fixing hole 1.21 in (30.75 mm) +/- 0.25 mm
Fixing mode
By screw
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1<br />Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end IEC 60947-1
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) IEC 60947-1
Shape of screw head
Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
[Ui] rated insulation voltage
600 V 3)IEC 60947-1
Signalling type
Steady
current consumption
14 mA
Service life
100000 h at rated voltage and 25 °C
Surge withstand
1 kV IEC 61000-4-5
Device presentation
Complete product
Supply voltage limits
100…132 V AC
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…131 °F (-40…55 °C)
Electrical shock protection class
Class I IEC 60536
IP degree of protection
IP66 IEC 60529<br />IP67 IEC 60529<br />IP69 IEC 60529<br />IP69K ISO 20653<br />Type 13 UL 50 E<br />Type 12 UL 50 E<br />Type 4 UL 50 E<br />Type 4X UL 50 E
IK degree of protection
IK06 conforming to IEC 50102
Standards
CSA C22.2 No 14<br />IEC 60947-5-1<br />IEC 60947-5-4<br />UL 508<br />IEC 60947-1<br />JIS C8201-5-1<br />CE<br />JIS C8201-1
Product Certifications
UL Listed<br />CSA<br />CCC<br />EAC
Vibration resistance
5 gn 10…500 Hz)IEC 60068-2-6<br />2 mm peak to peak 2…10 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27<br />25 gn 6 ms) 1000 shocks on each axis IEC 60068-2-27
Resistance to fast transients
2 kV IEC 61000-4-4
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge
6 kV on contact (on metal parts) IEC 61000-4-2<br />8 kV in free air (in insulating parts) IEC 61000-4-2
Electromagnetic emission
Class B IEC 55011

Specifications may be subject to change without notice