schneider XB5AG21C1

Selling Points

  • 1Designed to operate in harsh environments with high impact resistance up to IK06 rating.
  • 2Capable of 1 million operations, ensuring long-lasting performance in industrial applications.
  • 3Meets IEC, UL, CCC, EAC, JIS standards for global compatibility.
  • 4Offers excellent protection against dust and water, ensuring reliability in various conditions.
  • 5Simple and quick installation with a clip-together component system and anti-loosening screw clamp terminals.
Product Details
XB5AG21C1
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB5
Product or Component Type
Selector switch
Device short name
XB5
Bezel material
Plastic colour plated white
Head type
Standard
Mounting diameter
0.9 in (22 mm)
Sale per indivisible quantity
1
Shape of signaling unit head
Round
Type of operator
stay put
Operator profile
key switch
Operator position information
2 positions 90°
Type of Keylock
Key 455
Contacts type and composition
1 NO
Contact operation
Slow-break
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1
Height
1.7 in (42 mm)
Width
1.2 in (30 mm)
Depth
3.8 in (96 mm)
Terminals description ISO n°1
(13-14)NO
Net Weight
1.832 lb(US) (0.831 kg)
Resistance to high pressure washer
1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Key withdrawal position
Left
Contacts usage
Standard contacts
Positive opening
Without
Torque value
1.24 lbf.in (0.14 N.m) NO changing electrical state
Mechanical durability
1000000 cycles
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw head
Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
10 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)EN 60947-1
[Uimp] rated impulse withstand voltage
6 kV EN 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A600 EN/IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Λ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4<br />Λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
Device presentation
Complete product
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
Electrical shock protection class
Class II IEC 60536
IP degree of protection
IP66 IEC 60529<br />IP67
NEMA degree of protection
NEMA 13<br />NEMA 4X
IK degree of protection
IK06 conforming to IEC 50102
Standards
UL 508<br />CSA C22.2 No 14<br />EN/IEC 60947-5-1<br />EN/IEC 60947-5-4<br />EN/IEC 60947-1<br />JIS C8201-5-1<br />JIS C8201-1
Product Certifications
LROS (Lloyds register of shipping)<br />CSA<br />DNV<br />GL<br />BV<br />UL
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice