Product Model
ZB4BG6C

Selling Points
- 1Durable Construction: Made with chromium-plated metal bezel for long-lasting performance.
- 2IP66 Rating: Dust and water resistant, ideal for harsh environments.
- 3Easy Assembly: Quick and easy disassembly for maintenance and replacement.
- 4Versatile Connections: Compatible with screw clamp, connector, Faston connector, or spring terminal.
- 5Robust Design: Designed to withstand vibrations and impacts, ensuring stable operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Harmony XB4 | Product or Component Type | Head for key selector switch |
Device short name | ZB4 | Bezel material | Chromium plated metal |
Mounting diameter | 0.9 in (22 mm) | Head type | Standard |
Sale per indivisible quantity | 1 | Shape of signaling unit head | Round |
Return | Right to left | Operator profile | Black key switch |
Type of operator | Spring return | Operator position information | 2 positions 90° |
Type of Keylock | Special key | Product compatibility | 5 multi-chip |
Key withdrawal position | Left | CAD overall width | 1.1 in (29 mm) |
CAD overall height | 1.1 in (29 mm) | CAD overall depth | 2.8 in (72 mm) |
Resistance to high pressure washer | 1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m | Mechanical durability | 1000000 cycles |
Electrical composition code | C3 6 single front mounting<br />C4 6 single and double front mounting<br />C5 5 single front mounting<br />C6 5 single and double front mounting<br />C7 4 single front mounting<br />C8 4 single and double front mounting<br />C11 3 single front mounting<br />C15 1 single front mounting | Device presentation | Basic element |
Protective treatment | TH | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Ambient Air Temperature for Operation | -13…158 °F (-25…70 °C) | Overvoltage category | Class I IEC 60536 |
IP degree of protection | IP69K IEC 60529 | NEMA degree of protection | NEMA 13<br />NEMA 4X |
Standards | UL 508<br />CSA C22.2 No 14<br />EN/IEC 60947-5-4<br />GB 14048.5<br />EN/IEC 60947-1<br />EN/IEC 60947-5-5<br />EN/IEC 60947-5-1 | Product Certifications | UL Listed<br />LROS (Lloyds register of shipping)<br />CSA<br />BV<br />GL<br />DNV |
Vibration resistance | 5 gn 2…500 Hz)IEC 60068-2-6 | Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Specifications may be subject to change without notice