Product Model
ZB4BS14147

Selling Points
- 1Mechanical Latching: The ZB4BS14147 features a mechanical latching mechanism for secure operation.
- 2High Pressure Resistance: Resistant to high pressure washers with a pressure of 7,000,000 Pa at 55°C.
- 3IP66 Protection: Conforms to IEC 60529 with IP66 protection against dust and water.
- 4Vibration and Shock Resistance: Compliant with IEC 60068-2-6 and IEC 60068-2-27 standards for vibration and shock resistance.
- 5Sustainability Compliance: REACh free of SVHC and compliant with EU RoHS Directive for toxic heavy metal-free operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Harmony XB4 | Product or Component Type | Head for emergency switching off push-button |
Device short name | ZB4 | Bezel material | Black metal |
Mounting diameter | 0.9 in (22 mm) | Sale per indivisible quantity | 1 |
Shape of signaling unit head | Round | Type of operator | mechanical latching |
Reset | Key release | Operator profile | Red mushroom Ø 40 mm, unmarked |
Type of Keylock | Key 520E | Key withdrawal position | Center |
Head type | Standard | CAD overall width | 1.6 in (40 mm) |
CAD overall height | 1.6 in (40 mm) | CAD overall depth | 3.1 in (79 mm) |
Net Weight | 0.15 lb(US) (0.07 kg) | Resistance to high pressure washer | 1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m |
Mechanical durability | 300000 cycles | Electrical composition code | C7 4 single front mounting<br />C8 4 single and double front mounting<br />C11 3 single front mounting<br />C15 1 single front mounting<br />C10 4 single and double front mounting |
Protective treatment | TH | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) | Electrical shock protection class | Class I IEC 61140 |
IP degree of protection | IP66 IEC 60529<br />IP67<br />IP69<br />IP69K | NEMA degree of protection | NEMA 13<br />NEMA 4X<br />NEMA 4<br />NEMA 12 |
IK degree of protection | IK03 conforming to IEC 50102 | Standards | JIS C8201-5-1<br />GB 14048.5<br />EN/IEC 60947-5-4<br />IEC 60364-5-53<br />EN/IEC 60947-5-1<br />EN/IEC 60947-1<br />CSA C22.2 No 14<br />UL 508<br />JIS C8201-1 |
Product Certifications | BV<br />GL<br />UL Listed<br />LROS (Lloyds register of shipping)<br />DNV<br />CSA | Vibration resistance | 5 gn 2…500 Hz)IEC 60068-2-6 |
Shock resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Specifications may be subject to change without notice