schneider ZB4BVB1156

Selling Points

  • 1White Integral LED: The ZB4BVB1156 features a white integral LED for clear visibility.
  • 224V AC/DC Compatibility: Operates on 24V AC/DC, 50/60 Hz, ensuring versatility in various applications.
  • 3Robust Design: Built with Zamak fixing collar and screw clamp terminals for durability and secure mounting.
  • 4High Insulation Voltage: Rated at 600V (degree of pollution: 3) for enhanced safety and reliability.
  • 5Long Service Life: Designed to last with a service life of 100,000 hours at rated voltage and 25°C.
Product Details
ZB4BVB1156
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB4
Product or Component Type
Complete body/light block assembly
Device short name
ZB4
Fixing collar material
Zamak
Sale per indivisible quantity
1
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end
Light source
Universal LED
Bulb base
Integral LED
Light source colour
White
[Us] rated supply voltage
24 V AC/DC 50/60 Hz
CAD overall width
1.2 in (30 mm)
CAD overall height
1.9 in (47 mm)
CAD overall depth
1.5 in (37 mm)
Terminals description ISO n°1
(X1-X2)PL
Net Weight
0.137 lb(US) (0.062 kg)
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) IEC 60947-1
Shape of screw head
Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
[Ui] rated insulation voltage
600 V 3)IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-1
Signalling type
Steady
Supply voltage limits
19.2…30 V DC<br />21.6…26.4 V AC
current consumption
18 mA
Service life
100000 h at rated voltage and 25 °C
Surge withstand
1 kV IEC 61000-4-5
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
Electrical shock protection class
Class I IEC 60536
Standards
IEC 60947-5-5<br />IEC 60947-5-4<br />JIS C8201-5-1<br />IEC 60947-1<br />IEC 60947-5-1<br />UL 508<br />CSA C22.2 No 14<br />JIS C8201-1
Product Certifications
UL Listed<br />CSA
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Resistance to fast transients
2 kV IEC 61000-4-4
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge
6 kV on contact (on metal parts) IEC 61000-2-6<br />8 kV in free air (in insulating parts) IEC 61000-2-6
Electromagnetic emission
Class B IEC 55011

Specifications may be subject to change without notice