schneider ZB4BZ1019

Selling Points

  • 1High-Quality Switch Terminal: The ZB4BZ101 features silver alloy NO contacts for reliable performance.
  • 210A Contact Current Max: Designed to handle up to 10A of current, making it suitable for various commercial applications.
  • 3600V AC/DC Compatibility: Compatible with both AC and DC voltages up to 600V, ensuring versatility in electrical systems.
  • 4IP20 Protection Rating: Offers IP20 protection, ensuring the contact block is resistant to dust and water.
  • 5Easy Assembly and Disassembly: Features a snap fit head and body that can be tightened with a single screw, facilitating quick and secure mounting.
Product Details
ZB4BZ1019
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB4
Product or Component Type
Complete body/contact assembly
Device short name
ZB4
Fixing collar material
Zamak
Sale per indivisible quantity
1
Contacts type and composition
1 NO
Contact operation
Slow-break
Contact block type
Single
Device Composition
Contact block<br />Fixing collar
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1
CAD overall width
1.2 in (30 mm)
CAD overall height
1.9 in (47 mm)
CAD overall depth
1.5 in (37 mm)
Terminals description ISO n°1
(11-12)NO
Net Weight
0.141 lb(US) (0.064 kg)
Contacts usage
Standard contacts
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)<br />0.1 in (2.6 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating torque
0.44 lbf.in (0.05 N.m) NO changing electrical state
Mechanical durability
5000000 cycles
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
4 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
250 V 3)EN 60947-1
[Uimp] rated impulse withstand voltage
4 kV EN 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A300 EN/IEC 60947-5-1<br />0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1<br />0.22 A 125 V, DC-13, R300 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 1 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 1.5 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.15 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Λ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4<br />Λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
IP degree of protection
IP20 IEC 60529
Standards
EN/IEC 60947-5-4<br />EN/IEC 60947-1<br />JIS C8201-5-1<br />UL 508<br />EN/IEC 60947-5-5<br />EN/IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C8201-1
Product Certifications
BV<br />LROS (Lloyds register of shipping)<br />DNV<br />GL<br />CSA<br />UL
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice