schneider ZB5AV3

Selling Points

  • 1Easy Installation: Quickly replace and configure signaling units with simple screw-clamp connections.
  • 2High-Quality Materials: Constructed with durable plastic and designed for IP20 protection against live circuits.
  • 3Versatile Compatibility: Compatible with Harmony XB5 pilot lights and suitable for 110 to 120V AC.
  • 4Visual Distinction: Enables visual distinction of signaling units via illumination by BA9S base Integral LED.
  • 5Reliable Performance: Meets international standards including IEC 60947-1, CSA C22.2 No 14, and UL 508.
Product Details
ZB5AV3
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB5
Product or Component Type
Complete body/light block assembly
Device short name
ZB5
Fixing collar material
Plastic
Sale per indivisible quantity
1
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
Light source
Incandescent
Bulb base
BA 9s
Light block supply
Via integral transformer 1.2 VA 6 V
CAD overall width
1.2 in (30 mm)
CAD overall height
1.7 in (42 mm)
CAD overall depth
2.2 in (55 mm)
Terminals description ISO n°1
(X1-X2)PL
Net Weight
0.218 lb(US) (0.099 kg)
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) IEC 60947-1
Shape of screw head
Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
[Ui] rated insulation voltage
600 V 3)IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-1
Signalling type
Steady
[Us] rated supply voltage
110...120 V AC 50/60 Hz
Mounting of block
Front mounting
Electrical composition code
P4<br />M9
Device presentation
Basic sub-assemblies
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…131 °F (-40…55 °C)
Electrical shock protection class
Class II IEC 60536
Standards
JIS C8201-5-1<br />IEC 60947-5-1<br />IEC 60947-5-4<br />CSA C22.2 No 14<br />IEC 60947-1<br />UL 508<br />JIS C8201-1
Product Certifications
CSA<br />DNV<br />BV<br />LROS (Lloyds register of shipping)<br />UL Listed
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice