ZB5AW05D65
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB5
Product or Component Type
Complete body/contact assembly and light block
Device short name
ZB5
Fixing collar material
Plastic
Sale per indivisible quantity
1
Head type
Standard
Contacts type and composition
1 NO + 1 NC
Contact operation
Slow-break
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1
Light source
LED
Bulb base
BA 9s
Light block supply
Via integral transformer 1.2 VA 6 V
Light source colour
Blue
CAD overall width
1.2 in (30 mm)
CAD overall height
1.7 in (42 mm)
CAD overall depth
3.1 in (79 mm)
Terminals description ISO n°1
(11-12)NC<br />(13-14)NO
Net Weight
0.262 lb(US) (0.119 kg)
Contacts usage
Standard
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)<br />0.1 in (2.6 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating force
2 N NC changing electrical state<br />2.3 N NO changing electrical state
Operating torque
0.44 lbf.in (0.05 N.m) NO changing electrical state
Mechanical durability
5000000 cycles
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw head
Cross Philips no 1<br />Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
10 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)EN 60947-1
[Uimp] rated impulse withstand voltage
6 kV EN 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A600 EN/IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4<br />Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4
Signalling type
Steady
[Us] rated supply voltage
400 V AC 50/60 Hz
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
Electrical shock protection class
Class II IEC 60536
Standards
CSA C22.2 No 14<br />EN/IEC 60947-5-1<br />EN/IEC 60947-1<br />JIS C8201-5-1<br />UL 508<br />EN/IEC 60947-5-4<br />JIS C8201-1
Product Certifications
CSA<br />DNV<br />GL<br />LROS (Lloyds register of shipping)<br />UL Listed<br />BV
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice