schneider ZB6AF9

Selling Points

  • 1Flush Design: Compact and flush design for seamless integration into any panel.
  • 2Latching Mechanism: Reliable latching mechanism ensures consistent operation.
  • 36 Colored Caps: Choose from 6 colored caps for customizable signaling.
  • 4High Durability: Withstands 300,000 cycles of mechanical durability.
  • 5IP65 Protection: Robust IP65 protection against dust and water ingress.
Product Details
ZB6AF9
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB6
Product or Component Type
Head for illuminated push-button
Product Compatibility
Integral LED
Device short name
ZB6
Bezel material
Plastic
Mounting diameter
0.6 in (16 mm)
Sale per indivisible quantity
1
Shape of signaling unit head
Round
Type of operator
latching
Operator profile
6 colors choice flush, unmarked
Operator additional information
With set of 6 color cap
CAD overall width
0.7 in (18 mm)
CAD overall height
0.7 in (18 mm)
CAD overall depth
1.3 in (33 mm)
Net Weight
0.035 lb(US) (0.016 kg)
Resistance to high pressure washer
1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Mechanical durability
300000 cycles
Protective treatment
TC
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Electrical shock protection class
Class II IEC 61140
IP degree of protection
IP65 IEC 60529
NEMA degree of protection
NEMA 13 UL 50<br />NEMA 4 UL 50<br />NEMA 4X UL 50<br />NEMA 13 CSA C22.2 No 94<br />NEMA 4 CSA C22.2 No 94<br />NEMA 4X CSA C22.2 No 94
Standards
EN/IEC 60947-5-5<br />JIS C8201-5-1<br />EN/IEC 60947-5-1<br />EN/IEC 60947-1<br />JIS C 852<br />UL 508<br />CSA C22.2 No 14<br />JIS C8201-1
Product Certifications
UL<br />GOST<br />CCC<br />CSA
Vibration resistance
+/- 3 mm 2…500 Hz)IEC 60068-2-6<br />5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice