schneider ZB6ZG61B

Selling Points

  • 1High Amp Levels: Supports multiple amp levels for versatile use in industrial settings.
  • 2Durable Construction: Built with robust materials for long-lasting performance.
  • 3Compliant with Standards: Meets UL, CSA, and CE standards for safety and reliability.
  • 4Versatile Mounting Options: Easy installation with various mounting options available.
  • 5Enhanced Safety Features: Designed with safety in mind, ensuring secure electrical connections.
Product Details
ZB6ZG61B
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB6
Product or Component Type
Complete body for illuminated push-button
Device short name
ZB6
Fixing collar material
Plastic
Sale per indivisible quantity
1
Contacts type and composition
1 NO
Contact operation
Slow-break
Connections - terminals
Faston connector 2.8 x 0.5 mm
Light source
LED
Bulb base
Integral LED
Light source colour
Blue
[Us] rated supply voltage
48...120 V AC
CAD overall width
0.9 in (24 mm)
CAD overall height
0.7 in (18 mm)
CAD overall depth
2.008 in (51 mm)
Terminals description ISO n°1
(13-14)NO
Net Weight
0.013 lb(US) (0.006 kg)
Contacts usage
Standard
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.08 in (2 mm) NO changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating force
1.6 N NO changing electrical state
Contacts material
Silver alloy (Ag/Ni)
Short-circuit protection
6 A cartridge fuse gG EN/IEC 60947-5-1
[Ui] rated insulation voltage
250 V 3)EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV EN/IEC 60947-1
[Ie] rated operational current
3 A 120 V, AC-15, B300<br />1.5 A 240 V, AC-15, B300<br />0.1 A 250 V, DC-13, R300<br />0.22 A 125 V, DC-13, R300
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliability
Λ = 10exp(-8) 5 V 1 mA with confidence level of 90 % EN/IEC 60947-5-4
Signalling type
Steady
Supply voltage limits
6…30 V AC/DC
current consumption
15 mA
Surge withstand
1 kV direct contact IEC 61000-4-5<br />2 kV in free air IEC 61000-4-5
Protective treatment
TC
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Electrical shock protection class
Class II IEC 61140
Standards
UL 508<br />EN/IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C 4520<br />EN/IEC 60947-1<br />EN/IEC 60947-5-5<br />JIS C 852
Product Certifications
CSA<br />GOST<br />CCC<br />UL
Vibration resistance
+/- 3 mm 2…500 Hz)IEC 60068-2-6<br />5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Resistance to fast transients
2 kV IEC 61000-4-4
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge
6 kV on contact (on metal parts) IEC 61000-2-6<br />8 kV in free air (in insulating parts) IEC 61000-2-6
Electromagnetic emission
Class B IEC 55011

Specifications may be subject to change without notice