schneider ZBE1026

Selling Points

  • 1High-Reliability Contact Block: The ZBE1026 ensures safe and secure electrical connections with its gold flashed contacts.
  • 2Compact Design: Measures 22 mm in size, ideal for space-efficient installations.
  • 3Durable Construction: Withstands up to 10 million mechanical cycles for long-lasting performance.
  • 4Easy Installation: Front-mounted design with screw clamp terminals simplifies cabling without tools.
  • 5Wide Compatibility: Compatible with Harmony XB4 and XB5 control and signaling units for seamless integration.
Product Details
ZBE1026
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB4<br />Harmony XB5
Product or Component Type
Contact block
Device short name
ZBE
Sale per indivisible quantity
5
IP degree of protection
IP20 IEC 60529
Contact operation
Slow-break
Contact block type
Single
Contacts usage
Low power switching contacts
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
Net Weight
0.026 lb(US) (0.012 kg)
Contacts type and composition
1 NC
Positive opening
With IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating force
2 N NC changing electrical state
Mechanical durability
10000000 cycles
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) IEC 60947-1
Shape of screw head
Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Contacts material
Gold flashed (Ag/Ni/Au) contacts
Short-circuit protection
10 A cartridge fuse gG IEC 60947-5-1
[Ith] conventional free air thermal current
10 A IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV IEC 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 IEC 60947-5-1<br />6 A 120 V, AC-15, A600 IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Mounting of block
Front mounting
Electrical composition code
C1 9)<br />C2 7)<br />C3 6)<br />C4 4)<br />C5 5)<br />C6 3)<br />C7 4)<br />C8 2)<br />C9 3)<br />C12 6)<br />M1 6)<br />M2 4)<br />M3 4)<br />M5 2)<br />M6 2)<br />M7 6)<br />M8 4)<br />M9 2)<br />SF1 3)<br />SF2 2)<br />MF1 2)<br />MF2 2)<br />C10 2)<br />M4 2)<br />C13 1)
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
Standards
IEC 60947-5-4<br />IEC 60947-5-1<br />UL 508<br />JIS C8201-5-1<br />CSA C22.2 No 14<br />IEC 60947-1<br />JIS C8201-1
Product Certifications
GOST<br />LROS (Lloyds register of shipping)<br />CCC<br />BV<br />DNV<br />CSA<br />UL
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice