schneider ZBE1026TQ

Selling Points

  • 1Ensures consistent performance with electrical reliability of Λ < 10exp(-7) in clean environments.
  • 2Designed to withstand harsh environments with mechanical durability of 10,000,000 cycles.
  • 3Compatible with screw clamp terminals, ideal for various connection types including Faston connectors and spring terminals.
  • 4Equipped with short-circuit protection and rated insulation voltage of 600 V, ensuring safe operation.
  • 5Quick and easy assembly and disassembly for efficient maintenance and replacement.
Product Details
ZBE1026TQ
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB5<br />Harmony XB4
Product or Component Type
Contact block
Device short name
ZBE
Sale per indivisible quantity
100
IP degree of protection
IP20 IEC 60529
Contact operation
Slow-break
Contact block type
Single
Contacts usage
Low power switching contacts
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1<br />Screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1
Contacts type and composition
1 NC
Positive opening
With EN/IEC 60947-5-1 appendix K
Operating travel
0.06 in (1.5 mm) NC changing electrical state)<br />0.2 in (4.3 mm) total travel)
Operating force
2 N NC changing electrical state
Mechanical durability
10000000 cycles
Tightening torque
7.08…10.6 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw head
Cross pozidriv No 1<br />Slotted flat Ø 4 mm<br />Slotted flat Ø 5.5 mm
Contacts material
Gold flashed (Ag/Ni/Au) contacts
Short-circuit protection
10 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current
10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage
600 V 3)EN 60947-1
[Uimp] rated impulse withstand voltage
6 kV EN 60947-1
[Ie] rated operational current
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1<br />6 A 120 V, AC-15, A600 EN/IEC 60947-5-1<br />0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1<br />0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1<br />1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Electrical durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C<br />1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Mounting of block
Front mounting
Electrical composition code
C1 9)<br />C2 7)<br />C3 6)<br />C4 4)<br />C5 5)<br />C6 3)<br />C7 4)<br />C8 2)<br />C9 3)<br />C12 6)<br />M1 6)<br />M2 4)<br />M3 4)<br />M5 2)<br />M6 2)<br />M7 6)<br />M8 4)<br />M9 2)<br />SF1 3)<br />SF2 2)<br />MF1 2)<br />MF2 2)<br />C10 2)<br />M4 2)<br />C13 1)
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
Standards
EN/IEC 60947-1<br />UL 508<br />EN/IEC 60947-5-1<br />CSA C22.2 No 14<br />JIS C8201-5-1<br />EN/IEC 60947-5-4<br />JIS C8201-1
Product Certifications
LROS (Lloyds register of shipping)<br />DNV<br />GL<br />BV<br />GOST<br />UL<br />CSA<br />CCC
Vibration resistance
5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance
30 gn 18 ms) half sine wave acceleration IEC 60068-2-27<br />50 gn 11 ms) half sine wave acceleration IEC 60068-2-27

Specifications may be subject to change without notice