schneider ZBVG49

Selling Points

  • 1Integral LED Light: The ZBVG3 Harmony features an integral LED light module for clear and consistent illumination.
  • 2Robust Design: Built with screw clamp terminals and designed to withstand various environmental conditions, ensuring long-lasting performance.
  • 3Easy Installation: Simple to install with screw clamp terminals, making it a convenient choice for various applications.
  • 4High Reliability: Rated for 100,000 hours of service life at rated voltage and 25°C, ensuring high reliability in operation.
  • 5Compliance with Standards: Meets international standards including EN 60947-1, IEC 61000-4-5, and UL 508 for safety and performance assurance.
Product Details
ZBVG49
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Harmony XB4<br />Harmony XB5
Product or Component Type
Light block
Device short name
ZBV
Sale per indivisible quantity
5
Connections - terminals
Screw terminals for lug
Signalling type
Steady
Light source
Protected LED
Bulb base
Integral LED
Light block supply
Direct
Light source colour
Red
[Us] rated supply voltage
110...120 V
Net Weight
0.037 lb(US) (0.017 kg)
current consumption
14 mA
Service life
100000 h at rated voltage and 25 °C
Surge withstand
1 kV IEC 61000-4-5
Mounting of block
Front mounting
Electrical composition code
M1<br />M2<br />M3<br />M4<br />M5<br />M6<br />M10<br />MF1<br />P1<br />P2<br />PF1
Protective treatment
TH
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation
-40…158 °F (-40…70 °C)
IP degree of protection
IP20 IEC 60529
Standards
EN/IEC 60947-5-1<br />EN/IEC 60947-1<br />CSA C22.2 No 14<br />UL 508<br />JIS C8201-5-1<br />EN/IEC 60947-5-4<br />EN/IEC 60947-5-5<br />JIS C8201-1
Resistance to fast transients
2 kV IEC 61000-4-4
Resistance to electromagnetic fields
9.1 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge
6 kV on contact (on metal parts) IEC 61000-4-2<br />8 kV in free air (in insulating parts) IEC 61000-4-2
Electromagnetic emission
Class B IEC 55011

Specifications may be subject to change without notice