Product Model

ARS60-A4A00072

In Stock
Last updated: 2025/4/19
sick ARS60-A4A00072

Selling Points

  • 1Achieves a maximum resolution of 72 steps per revolution with an error limit of 0.046° (non-binary number of steps).
  • 2Features a solid shaft with a face mount flange, made from aluminum die cast, ensuring durability and stability.
  • 3Measures 19 mm in length and 10 mm in diameter, making it ideal for space-constrained applications.
  • 4Operates at temperatures from -20°C to +85°C and can withstand up to 90% relative humidity.
  • 5Designed to last with a bearing lifetime of 3.6 x 10^9 revolutions and a mean time to dangerous failure of 300 years.
Product Details
ARS60-A4A00072
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
72
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
SSI
Initialization time
80 ms
Code type
Gray
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Male connector, M23, 12-pin, radial
Supply voltage
10 ... 32 V
Operating current
Typ. 60 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Solid shaft, face mount flange
Shaft diameter
10 mm
Shaft length
19 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.4 Ncm
Operating torque
Typ. 0.3 Ncm
Permissible shaft loading
20 N (radial)#!#10 N (axial)
Operating speed
≤ 6,000 min⁻¹ with shaft seal#!#≤ 10,000 min⁻¹ without shaft seal2)
Moment of inertia of the rotor
54 gcm²
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice