Product Model

ARS60-AAK08192

In Stock
Last updated: 2025/4/19
sick ARS60-AAK08192

Selling Points

  • 1Achieves 8,192 steps per revolution for precise measurements.
  • 2Allows for tailor-made solutions with various shaft diameters and interfaces.
  • 3IP65 protection class ensures durability in harsh environments.
  • 4Simple zero adjustment via button or remote signal line.
  • 5Operates from -20°C to +85°C with 10-32V DC supply voltage.
Product Details
ARS60-AAK08192
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
8,192 (13 bit)
Measuring step
360° /number of steps
Measuring step deviation
0.005° binary number of steps
Error limits G
0.035° (binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
SSI
Initialization time
80 ms
Code type
Gray
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Cable, 11-wire, radial, 1.5 m
Supply voltage
10 ... 32 V
Operating current
Typ. 60 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Blind hollow shaft
Shaft diameter
15 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.6 Ncm
Operating torque
Typ. 0.4 Ncm
Permissible movement static
± 0.3 mm (radial)#!#± 0.5 mm (axial)
Permissible movement dynamic
± 0.1 mm (radial)#!#± 0.2 mm (axial)
Operating speed
≤ 3,000 min⁻¹
Moment of inertia of the rotor
See figure
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice