Product Model

ARS60-ADA09000

In Stock
Last updated: 2025/4/19
sick ARS60-ADA09000

Selling Points

  • 1High precision with up to 9,000 steps per revolution.
  • 2Robust design for maximum system availability in extreme environmental conditions.
  • 3Through hollow shaft interface for versatile mounting options.
  • 4Excellent repeatability with a standard deviation of 0.005°.
  • 5Compact and lightweight design with an approximate weight of 0.3 kg.
Product Details
ARS60-ADA09000
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
9,000
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
SSI
Initialization time
80 ms
Code type
Gray
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Male connector, M23, 12-pin, radial
Supply voltage
10 ... 32 V
Operating current
Typ. 60 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Through hollow shaft
Shaft diameter
12 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 2.2 Ncm
Operating torque
Typ. 1.6 Ncm
Permissible movement static
± 0.3 mm (radial)#!#± 0.5 mm (axial)
Permissible movement dynamic
± 0.1 mm (radial)#!#± 0.2 mm (axial)
Operating speed
≤ 3,000 min⁻¹
Moment of inertia of the rotor
See figure
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice