Product Model

ARS60-F4R00720

In Stock
Last updated: 2025/4/20
sick ARS60-F4R00720

Selling Points

  • 1Up to 15 bits (32,768 increments) for precise position measurement.
  • 2Solid shaft with face mount flange, suitable for various mounting methods.
  • 3Operating temperature range from -20°C to +85°C and storage range from -40°C to +100°C.
  • 4Aluminum housing with IP66 enclosure rating, resistant to shocks and vibrations.
  • 5Available with SSI and parallel interfaces, including gray code and BCD types.
Product Details
ARS60-F4R00720
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
720
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
Gray
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Cable, 22-wire, axial, 1.5 m
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Solid shaft, face mount flange
Shaft diameter
10 mm
Shaft length
19 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.4 Ncm
Operating torque
Typ. 0.3 Ncm
Permissible shaft loading
20 N (radial)#!#10 N (axial)
Operating speed
≤ 6,000 min⁻¹ with shaft seal#!#≤ 10,000 min⁻¹ without shaft seal2)
Moment of inertia of the rotor
54 gcm²
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice