Product Model

ARS60-FDA00512

In Stock
Last updated: 2025/4/18
sick ARS60-FDA00512

Selling Points

  • 1High Precision Measurement: The ARS60-FDA00512 features 512 steps per revolution, ensuring precise singleturn measurements.
  • 2Robust Mechanical Design: Constructed with aluminum die cast housing, this encoder offers durability and resistance to environmental factors.
  • 3Compact Size: With a shaft diameter of 10 mm and a length of 19 mm, it fits seamlessly into various industrial automation setups.
  • 4Wide Operating Range: Operates within -20°C to +85°C, making it suitable for diverse industrial environments.
  • 5Reliable Performance: Designed with a start-up torque of 0.4 Ncm and an operating torque of 0.3 Ncm, ensuring smooth and reliable operation.
Product Details
ARS60-FDA00512
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
512 (9 bit)
Measuring step
360° /number of steps
Measuring step deviation
0.005° binary number of steps
Error limits G
0.035° (binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
Gray
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Male connector, M23, 21-pin, radial
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Through hollow shaft
Shaft diameter
12 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 2.2 Ncm
Operating torque
Typ. 1.6 Ncm
Permissible movement static
± 0.3 mm (radial)#!#± 0.5 mm (axial)
Permissible movement dynamic
± 0.1 mm (radial)#!#± 0.2 mm (axial)
Operating speed
≤ 3,000 min⁻¹
Moment of inertia of the rotor
See figure
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice