Product Model

ARS60-GAA02280

In Stock
Last updated: 2025/4/18
sick ARS60-GAA02280

Selling Points

  • 1Up to 15 bits (32,768 increments) for precise position measurement.
  • 2IP66 enclosure rating and resistance to extreme environmental conditions.
  • 3Compatible with SSI and parallel interfaces, including gray code and binary types.
  • 4Ideal for installations with limited space due to its compact design.
  • 5Mean time to dangerous failure (MTTFd) of 300 hours, ensuring consistent performance over time.
Product Details
ARS60-GAA02280
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
2,280
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
Gray, trimmed
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Male connector, M23, 21-pin, radial
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Blind hollow shaft
Shaft diameter
15 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.6 Ncm
Operating torque
Typ. 0.4 Ncm
Permissible movement static
± 0.3 mm (radial)#!#± 0.5 mm (axial)
Permissible movement dynamic
± 0.1 mm (radial)#!#± 0.2 mm (axial)
Operating speed
≤ 3,000 min⁻¹
Moment of inertia of the rotor
See figure
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice