Product Model

ARS60-H4M18000

In Stock
Last updated: 2025/4/18
sick ARS60-H4M18000

Selling Points

  • 1Up to 15 bits resolution (32,768 increments) for precise position measurement.
  • 2Tailor-made solutions with interchangeable collets for different shaft diameters.
  • 3IP65 and IP66 enclosure ratings for resistance to environmental conditions.
  • 4Simple zero-set function via button or signal line for quick setup.
  • 5Operating voltage range of 10 V DC to 32 V DC with low power consumption (60 mA SSI, 90 mA parallel).
Product Details
ARS60-H4M18000
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
18,000
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
Binary
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Cable, 22-wire, radial, 5 m
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Solid shaft, face mount flange
Shaft diameter
10 mm
Shaft length
19 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.4 Ncm
Operating torque
Typ. 0.3 Ncm
Permissible shaft loading
20 N (radial)#!#10 N (axial)
Operating speed
≤ 6,000 min⁻¹ with shaft seal#!#≤ 10,000 min⁻¹ without shaft seal2)
Moment of inertia of the rotor
54 gcm²
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice