Product Model

ARS60-HAM00360

In Stock
Last updated: 2025/4/19
sick ARS60-HAM00360

Selling Points

  • 1High Resolution: Up to 16 bits for precise position feedback.
  • 2Robust Design: IP67 protection rating for harsh environments.
  • 3Versatile Output: Supports SSI and CANopen interfaces for integration into various control systems.
  • 4Wide Operating Range: Operates on 4.5 to 30 V DC and functions in -40°C to +85°C temperatures.
  • 5Flexible Mounting: Offers through-shaft and blind-shaft configurations for diverse installation needs.
Product Details
ARS60-HAM00360
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
360
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
Binary
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Cable, 22-wire, radial, 5 m
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Blind hollow shaft
Shaft diameter
15 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.6 Ncm
Operating torque
Typ. 0.4 Ncm
Permissible movement static
± 0.3 mm (radial)#!#± 0.5 mm (axial)
Permissible movement dynamic
± 0.1 mm (radial)#!#± 0.2 mm (axial)
Operating speed
≤ 3,000 min⁻¹
Moment of inertia of the rotor
See figure
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice