Product Model

ARS60-HDA05000

In Stock
Last updated: 2025/4/19
sick ARS60-HDA05000

Selling Points

  • 1Resolves up to 15 bits (32,768 increments) for precise position measurement.
  • 2Withstands extreme environmental conditions and ensures maximum system availability.
  • 3Supports SSI with gray code type or gray capped, parallel with gray, gray capped, binary, and BCD code types.
  • 4Specially suited for tight installation spaces due to its compact design.
  • 5Provides valid positional data within 80 ms initialization time.
Product Details
ARS60-HDA05000
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
5,000
Measuring step
360° /number of steps
Measuring step deviation
0.016° non-binary number of steps
Error limits G
0.046° (non-binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
Binary
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Male connector, M23, 21-pin, radial
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Through hollow shaft
Shaft diameter
12 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 2.2 Ncm
Operating torque
Typ. 1.6 Ncm
Permissible movement static
± 0.3 mm (radial)#!#± 0.5 mm (axial)
Permissible movement dynamic
± 0.1 mm (radial)#!#± 0.2 mm (axial)
Operating speed
≤ 3,000 min⁻¹
Moment of inertia of the rotor
See figure
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice