Product Model

ARS60-J1B01024

In Stock
Last updated: 2025/4/19
sick ARS60-J1B01024

Selling Points

  • 11,024 steps per revolution for precise position measurement.
  • 2Solid shaft and servo flange with a diameter of 6 mm x 10 mm.
  • 3Protected against dust and water, ensuring reliable operation in harsh environments.
  • 480 ms initialization time for quick setup and operation.
  • 5–20 °C to +85 °C, suitable for various industrial conditions.
Product Details
ARS60-J1B01024
sick

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Number of steps per revolution (max. resolution)
1,024 (10 bit)
Measuring step
360° /number of steps
Measuring step deviation
0.005° binary number of steps
Error limits G
0.035° (binary number of steps)
Repeatability standard deviation σr
0.005°
Communication interface
Parallel data world
Initialization time
80 ms
Code type
BCD
Code sequence parameter adjustable
CW (clockwise) increasing when viewing the clockwise rotating shaft
Measured value backlash
0.005°
Response threshold
0.003°
Connection type
Male connector, M23, 21-pin, axial
Supply voltage
10 ... 32 V
Operating current
Typ. 90 mA
MTTFd: mean time to dangerous failure
300 years (EN ISO 13849-1)
Switching level of control inputs
Logic H = 0.7 x U#!#, Logic L = 0 V ... 0.3 x U
Actuation of set button
≥ 100 ms
Mechanical design
Solid shaft, Servo flange
Shaft diameter
6 mm
Shaft length
10 mm
Weight
Approx. 0.3 kg
Housing material
Aluminum die cast
Start up torque
Typ. 0.25 Ncm
Operating torque
Typ. 0.2 Ncm
Permissible shaft loading
20 N (radial)#!#10 N (axial)
Operating speed
≤ 6,000 min⁻¹ with shaft seal#!#≤ 10,000 min⁻¹ without shaft seal2)
Moment of inertia of the rotor
48 gcm²
Bearing lifetime
3.6 x 10#!#revolutions
Angular acceleration
≤ 500,000 rad/s²

Specifications may be subject to change without notice